SenseLive X3050 Missing Authorization
Summary
| CVE | CVE-2026-40623 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-04-24 00:16:28 UTC |
| Updated | 2026-04-28 19:02:30 UTC |
| Description | A vulnerability in SenseLive X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable. |
Risk And Classification
Primary CVSS: v4.0 7.2 HIGH from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.000340000 probability, percentile 0.101160000 (date 2026-04-26)
Problem Types: CWE-862 | CWE-862 CWE-862 Missing Authorization
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 7.2 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7.2 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 8.1 | HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H |
| 3.1 | CNA | CVSS | 8.1 | HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H |
CVSS v4.0 Breakdown
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Senselive | X3500 | - | All | All | All |
| Operating System | Senselive | X3500 Firmware | 1.523 | All | All | All |
Vendor Declared Affected Products
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.cisa.gov/news-events/ics-advisories/icsa-26-111-12 | [email protected] | www.cisa.gov | US Government Resource |
| github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-11... | [email protected] | github.com | Third Party Advisory |
| senselive.io/contact | [email protected] | senselive.io | Product |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Jithin Nambiar J reported these vulnerabilities to CISA. (en)
Additional Advisory Data
Solutions
CNA: SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact