Hydro-Québec Le Circuit Electrique charging station backend Insufficient Session Expiration
Summary
| CVE | CVE-2026-44383 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-07-10 23:16:48 UTC |
| Updated | 2026-07-10 23:16:48 UTC |
| Description | Multiple connections to the backend using the same charging station ID are allowed, which could allow an attacker to deploy multiple instances of malicious OCPP clients to overwhelm the backend. |
Risk And Classification
Primary CVSS: v4.0 8.7 HIGH from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-613 | CWE-613 CWE-613
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 3.1 | CNA | CVSS | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
CVSS v4.0 Breakdown
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Hydro-Qubec | Le Circuit Electrique Charging Station Backend | affected June_2026 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-18... | [email protected] | github.com | |
| www.cisa.gov/news-events/ics-advisories/icsa-26-188-01 | [email protected] | www.cisa.gov | |
| www.hydroquebec.com/nous-joindre | [email protected] | www.hydroquebec.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: An anonymous researcher reported this vulnerability to CISA (en)
Additional Advisory Data
Solutions
CNA: Hydro-Québec has updated the majority of charging stations to disable OCPP, mitigating the risk of exploitation. Hydro-Québec has also implemented authentication systems to mitigate the issue for certain charging stations which are still reliant on OCPP. Contact Hydro-Québec with any additional questions.