Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor

Summary

CVECVE-2026-4638
StatePUBLISHED
AssignerSEC-VLab
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-09-24 11:16:45 UTC
Updated2026-09-24 20:43:32 UTC
DescriptionPRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Risk And Classification

Primary CVSS: v4.0 7.1 HIGH from 551230f0-3615-47bd-b7cc-93e92e730bbf

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS: 0.002680000 probability, percentile 0.169010000 (date 2026-09-25)

Problem Types: CWE-209 | CWE-209 CWE-209 Generation of error message containing sensitive information


VersionSourceTypeScoreSeverityVector
4.0551230f0-3615-47bd-b7cc-93e92e730bbfSecondary7.1HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/C...
4.0CNACVSS7.1HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS v4.0 Breakdown

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Confidentiality
High
Integrity
None
Availability
None
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Paessler GmbH PRTG Network Monitor affected 26.2.120.1449 custom Not specified

References

ReferenceSourceLinkTags
www.paessler.com/prtg/prtg-network-monitor 551230f0-3615-47bd-b7cc-93e92e730bbf www.paessler.com
paessler.freshdesk.com/en/support/solutions/articles/76000088640 551230f0-3615-47bd-b7cc-93e92e730bbf paessler.freshdesk.com
www.paessler.com/de/download 551230f0-3615-47bd-b7cc-93e92e730bbf www.paessler.com
r.sec-consult.com/paessler 551230f0-3615-47bd-b7cc-93e92e730bbf r.sec-consult.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: J. Kruchem, SEC Consult Vulnerability Lab (en)

CNA: S. Michlits, SEC Consult Vulnerability Lab (en)

Additional Advisory Data

Solutions

CNA: Upgrade to Paessler PRTG Network Monitor version 26.2.120.1449 or later.

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report