Undocumented factory accounts
Summary
| CVE | CVE-2026-4642 |
|---|---|
| State | PUBLISHED |
| Assigner | ABB |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-11-27 15:17:40 UTC |
| Updated | 2026-11-27 15:17:40 UTC |
| Description | Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615. This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0. |
Risk And Classification
Primary CVSS: v4.0 7.5 HIGH from [email protected]
CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:U/V:D/RE:M/U:Amber
Problem Types: CWE-863 | CWE-863 CWE-863 Incorrect Authorization
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 7.5 | HIGH | CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7.5 | HIGH | CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/A... |
| 3.1 | [email protected] | Secondary | 6.6 | MEDIUM | CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | CNA | CVSS | 6.6 | MEDIUM | CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
HighAttack Requirements
PresentPrivileges Required
HighUser Interaction
NoneConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:U/V:D/RE:M/U:Amber
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
HighPrivileges Required
HighUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | ABB | Relion Protection Relays REX610 | affected 1.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays REX610 | affected 1.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays REX610 | affected 1.2 custom | Not specified |
| CNA | ABB | Relion Protection Relays RE 611 IEC/CN | affected 1.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays RE 611 IEC/CN | affected 2.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays RBX615 | affected 1.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays RBX615 | affected 2.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays REF615 ANSI | affected 4.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays REF615R ANSI | affected 4.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays REF615R ANSI | affected 4.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays RER615 | affected 1.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays RER615 | affected 1.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays RER615 | affected 2.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays REC615 | affected 1.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays REC615 | affected 1.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays REC615 | affected 2.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays REX615 | affected PCL1 (6.0) custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series IEC | affected 3.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series IEC | affected 4.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series IEC | affected 4.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series IEC | affected 5.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series IEC | affected 5.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series CN | affected 3.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series CN | affected 4.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series CN | affected 5.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series ANSI | affected 4.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series ANSI | affected 4.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series ANSI | affected 4.0 FP2 custom | Not specified |
| CNA | ABB | Relion Protection Relays 615 Series ANSI | affected 5.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays RER620 ANSI | affected 1.1 custom | Not specified |
| CNA | ABB | Relion Protection Relays RER620 ANSI | affected 1.2 custom | Not specified |
| CNA | ABB | Relion Protection Relays RER620 ANSI | affected 1.3 custom | Not specified |
| CNA | ABB | Relion Protection Relays 620 Series ANSI | affected 2.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays 620 Series ANSI | affected 2.0 FP1 custom | Not specified |
| CNA | ABB | Relion Protection Relays 620 Series IEC/CN | affected 2.0 custom | Not specified |
| CNA | ABB | Relion Protection Relays 620 Series IEC/CN | affected 2.0 FP1 custom | Not specified |
| CNA | ABB | Substation Merging Unit SMU615 | affected 1.0 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| search.abb.com/library/Download.aspx | [email protected] | search.abb.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.