CVE-2026-50063
Summary
| CVE | CVE-2026-50063 |
|---|---|
| State | PUBLISHED |
| Assigner | siemens |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-08-11 13:18:58 UTC |
| Updated | 2026-08-11 15:17:30 UTC |
| Description | A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
Risk And Classification
Primary CVSS: v4.0 7.3 HIGH from [email protected]
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.001130000 probability, percentile 0.016590000 (date 2026-08-12)
Problem Types: CWE-125 | CWE-125 CWE-125: Out-of-bounds Read
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 7.3 | HIGH | CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | DECLARED | 7.3 | HIGH | CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
| 3.1 | CNA | DECLARED | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
CVSS v4.0 Breakdown
Attack Vector
LocalAttack Complexity
HighAttack Requirements
NonePrivileges Required
NoneUser Interaction
PassiveConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
LocalAttack Complexity
LowPrivileges Required
NoneUser Interaction
RequiredScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Siemens | Solid Edge SE2025 | affected V225.0 Update 15 custom | Not specified |
| CNA | Siemens | Solid Edge SE2026 | affected V226.0 Update 7 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/html/ssa-621657.html | [email protected] | cert-portal.siemens.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.