Information Disclosure through Action Parameters in Venafi app for Splunk SOAR
Summary
| CVE | CVE-2026-76385 |
|---|---|
| State | PUBLISHED |
| Assigner | cisco |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-08-19 22:17:24 UTC |
| Updated | 2026-08-20 17:19:47 UTC |
| Description | In versions below 2.1.4 of the Venafi app for Splunk SOAR, a user who holds a role with permission to run actions could expose keystore and private-key passwords by invoking the get certificate action, because the action's keystore_password and password parameters are not masked and are shown in cleartext in the user interface. The information disclosure is possible because the app does not mark the affected action parameters as passwords. For more information see Run an action in Splunk SOAR (https://help.splunk.com/en/splunk-soar/soar-on-premises/use-splunk-soar-on-premises/8.6.0/use-the-command-line-interface-to-perform-tasks-in-splunk-soar-on-premises/run-an-action-in-splunk-soar-on-premises). |
Risk And Classification
Primary CVSS: v3.1 4.3 MEDIUM from [email protected]
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Problem Types: CWE-312 | CWE-312 The application stores sensitive information in cleartext within a resource that might be accessible to another control sphere.
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Secondary | 4.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N |
| 3.1 | CNA | CVSS | 4.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N |
CVSS v3.1 Breakdown
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Splunk | Venafi App For Splunk SOAR | affected 2.1 2.1.4 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| advisory.splunk.com/advisories/SVD-2026-0806 | [email protected] | advisory.splunk.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Additional Advisory Data
Solutions
CNA: Upgrade each affected Splunk SOAR connector to the applicable fixed version listed in Product Status. The fixed app version requires Splunk SOAR 8.6.0 or higher.
Workarounds
CNA: Turn off or remove the Venafi app for Splunk SOAR. For more information see [Add and configure apps and assets to provide actions in Splunk SOAR](https://help.splunk.com/en/splunk-soar/soar-on-premises/administer-soar-on-premises/8.6.0/manage-your-splunk-soar-on-premises-apps-and-assets/add-and-configure-apps-and-assets-to-provide-actions-in-splunk-soar-on-premises) in the Splunk documentation. Note: Turning off the app stops all actions configured through it from running.