Cleartext Storage of Sensitive Information in boneIO

Summary

CVECVE-2026-77054
StatePUBLISHED
AssignerCERT-PL
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-10-26 15:16:42 UTC
Updated2026-10-26 17:17:29 UTC
DescriptionboneIO Black stores passwords, including the MQTT broker and web panel passwords, in cleartext. The GET /api/config endpoint returns the full configuration with sub-services passwords exposed. Any authenticated user can call the endpoint and access the administrative passwords in cleartext form. Critically, due to CVE-2026-77053 (authentication disabled by default), an unauthenticated attacker on the same local network can retrieve all passwords. This issue was fixed in version 1.6.0: web panel passwords are stored as salted scrypt hashes in a file readable only by the service account, and the API and logs no longer return secret values. The MQTT broker password has to stay recoverable because the application presents it to the broker as a client; it is kept in a separate file readable only by the service account and is no longer exposed through the API.

Risk And Classification

Primary CVSS: v4.0 6.9 MEDIUM from [email protected]

CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Problem Types: CWE-312 | CWE-312 CWE-312 Cleartext Storage of Sensitive Information


VersionSourceTypeScoreSeverityVector
4.0[email protected]Secondary6.9MEDIUMCVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/C...
4.0CNACVSS6.9MEDIUMCVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS v4.0 Breakdown

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Confidentiality
High
Integrity
None
Availability
None
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA BoneIO BoneIO affected 1.2.0 1.6.0 semver Not specified

References

ReferenceSourceLinkTags
boneio.eu/en/docs/black [email protected] boneio.eu
cert.pl/en/posts/2026/10/CVE-2026-77052 [email protected] cert.pl
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Mateusz Włodarczak (s3ga) (en)

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report