CVE-2026-78557

Summary

CVECVE-2026-78557
StatePUBLISHED
Assignersiemens
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-10-13 10:17:20 UTC
Updated2026-10-15 20:38:04 UTC
DescriptionA vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim's machine

Risk And Classification

Primary CVSS: v4.0 7.7 HIGH from [email protected]

CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS: 0.004520000 probability, percentile 0.377840000 (date 2026-10-15)

Problem Types: CWE-79 | CWE-79 CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')


VersionSourceTypeScoreSeverityVector
4.0[email protected]Secondary7.7HIGHCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C...
4.0CNADECLARED7.7HIGHCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
3.1[email protected]Secondary8.3HIGHCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
3.1CNADECLARED8.3HIGHCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H

CVSS v4.0 Breakdown

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
Present
Privileges Required
None
User Interaction
Passive
Confidentiality
High
Integrity
High
Availability
High
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
Required
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Siemens Industrial Edge App Publisher affected V1.27.9 custom Not specified

References

ReferenceSourceLinkTags
cert-portal.siemens.com/productcert/html/ssa-968435.html [email protected] cert-portal.siemens.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report