Comelit 1456B gateway allows low priviledge user to overwrite installer password via unauthorized endpoint

Summary

CVECVE-2026-80275
StatePUBLISHED
AssignerNCSC-FI
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-10-01 06:17:09 UTC
Updated2026-10-01 16:18:00 UTC
DescriptionComelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 fail to enforce server-side authorization on an administrative password-change function. An authenticated user level can invoke this function to overwrite the installer (administrator) account password.

Risk And Classification

Primary CVSS: v3.1 8.8 HIGH from db4dfee8-a97e-4877-bfae-eba6d14a2166

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

EPSS: 0.002370000 probability, percentile 0.133430000 (date 2026-10-02)

Problem Types: CWE-425 | CWE-425 CWE-425 Direct Request ('Forced Browsing')


VersionSourceTypeScoreSeverityVector
3.1db4dfee8-a97e-4877-bfae-eba6d14a2166Secondary8.8HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
3.1CNACVSS8.8HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Comelit Group S.p.A. 1456B Multi-User Gateway affected 2.9.1 Firmware
CNA Comelit Group S.p.A. 1456B Multi-User Gateway affected 2.10.0 Firmware

References

ReferenceSourceLinkTags
pro.comelitgroup.com/en-us/product/1456B db4dfee8-a97e-4877-bfae-eba6d14a2166 pro.comelitgroup.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Teemu Tapanila (en)

CNA: Juha Jussila (en)

Additional Advisory Data

SourceTimeEvent
CNA2026-03-22T00:00:00.000ZVulnerability discovered during web endpoint authorization testing and reported to Comelit
CNA2026-03-30T00:00:00.000ZComelit acknowledged receipt and assigned vendor tracking ID VMP-40
CNA2026-04-10T00:00:00.000ZComelit declined to remediate, classifying the behavior as intended; finder contested this classification as a breach of privilege separation
CNA2026-06-06T00:00:00.000ZCoordinated disclosure filed with NCSC-FI (Traficom) requesting vendor coordination

Workarounds

CNA: The vendor does not consider this a defect and has stated it will not be fixed, so the device's built-in role separation cannot be relied upon. As a mitigation, treat every account on the device as an administrator-equivalent account. Additionally, restrict network access to the device management interface to trusted administrators only.

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.