CVE-2026-82766
Summary
| CVE | CVE-2026-82766 |
|---|---|
| State | PUBLISHED |
| Assigner | jpcert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-09-14 07:17:17 UTC |
| Updated | 2026-09-14 12:17:46 UTC |
| Description | Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SGA1000. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product. |
Risk And Classification
Primary CVSS: v4.0 8.7 HIGH from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-78 | CWE-78 Improper neutralization of special elements used in an OS command ('OS Command Injection')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 8.8 | HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | CNA | CVSS | 8.8 | HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowAttack Requirements
NonePrivileges Required
LowUser Interaction
NoneConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
LowUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Contec Co. Ltd. | SGA1000 | affected 1.02 semver | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.contec.com/api/downloadlogger | [email protected] | www.contec.com | |
| jvn.jp/en/vu/JVNVU99009004 | [email protected] | jvn.jp | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.