RF Replay of control commands
Summary
| CVE | CVE-2026-82948 |
|---|---|
| State | PUBLISHED |
| Assigner | ENISA |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-11-19 11:17:08 UTC |
| Updated | 2026-11-19 16:21:59 UTC |
| Description | The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to impersonate activity. The attacker can also disarm or arm the system at will if a Nexsmart keypad (product link) is in use, thus compromising the functionality of the alarm system completely. |
Risk And Classification
Primary CVSS: v4.0 7.1 HIGH from a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-294 | CWE-294 CWE-294: Authentication Bypass by Capture-replay
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | a6d3dc9e-0591-4a13-bce7-0f5b31ff6158 | Secondary | 7.1 | HIGH | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7.1 | HIGH | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N |
CVSS v4.0 Breakdown
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Onyx Cookware ApS | Nexsmart Guardian 2 Alarm System | affected semver | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardia... | a6d3dc9e-0591-4a13-bce7-0f5b31ff6158 | medium.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Elias Lindström (en)
CNA: CERT-SE (en)
Additional Advisory Data
Solutions
CNA: Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart through its official support channels and ask about any current remediation guidance.