CareCam CM2507 Missing Authentication for Critical Function
Summary
| CVE | CVE-2026-84400 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-09-18 16:17:12 UTC |
| Updated | 2026-09-19 15:17:05 UTC |
| Description | CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access. |
Risk And Classification
Primary CVSS: v4.0 2.3 LOW from [email protected]
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.001410000 probability, percentile 0.038020000 (date 2026-09-21)
Problem Types: CWE-306 | CWE-306 CWE-306
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 2.3 | LOW | CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 2.3 | LOW | CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 3.1 | LOW | CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N |
| 3.1 | CNA | CVSS | 3.1 | LOW | CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N |
CVSS v4.0 Breakdown
Attack Vector
AdjacentAttack Complexity
LowAttack Requirements
PresentPrivileges Required
NoneUser Interaction
NoneConfidentiality
NoneIntegrity
LowAvailability
NoneSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
AdjacentAttack Complexity
HighPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
NoneIntegrity
LowAvailability
NoneCVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | CareCam | HMT.CM2507 Firmware | affected v251211.1507 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-25... | [email protected] | github.com | |
| www.cisa.gov/news-events/ics-advisories/icsa-26-258-08 | [email protected] | www.cisa.gov | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Ben Law reported this vulnerability to CISA. (en)
Additional Advisory Data
Workarounds
CNA: CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
There are currently no legacy QID mappings associated with this CVE.