CareCam CM2507 Missing Authentication for Critical Function
Summary
| CVE | CVE-2026-88259 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-09-18 16:17:14 UTC |
| Updated | 2026-09-18 19:03:28 UTC |
| Description | CareCam CM2507 IP cameras do not require authentication for access to its network video streaming service. An unauthenticated attacker with network access to the affected device could retrieve live camera video. |
Risk And Classification
Primary CVSS: v4.0 8.7 HIGH from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-306 | CWE-306 CWE-306
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
| 3.1 | CNA | CVSS | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowAttack Requirements
NonePrivileges Required
NoneUser Interaction
NoneConfidentiality
HighIntegrity
NoneAvailability
NoneSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
NoneAvailability
NoneCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | CareCam | HMT.CM2507 Firmware | affected v251211.1507 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-25... | [email protected] | github.com | |
| www.cisa.gov/news-events/ics-advisories/icsa-26-258-08 | [email protected] | www.cisa.gov | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Ben Law reported this vulnerability to CISA. (en)
Additional Advisory Data
Workarounds
CNA: CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
There are currently no legacy QID mappings associated with this CVE.