Studio 5000 Logix Designer® – Multiple Vulnerabilities
Summary
| CVE | CVE-2026-9108 |
|---|---|
| State | PUBLISHED |
| Assigner | Rockwell |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-07-14 16:17:05 UTC |
| Updated | 2026-07-14 16:46:49 UTC |
| Description | A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution. |
Risk And Classification
Primary CVSS: v4.0 5.4 MEDIUM from [email protected]
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-22 | CWE-22 CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 5.4 | MEDIUM | CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 5.4 | MEDIUM | CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CVSS v4.0 Breakdown
Attack Vector
LocalAttack Complexity
HighAttack Requirements
PresentPrivileges Required
LowUser Interaction
ActiveConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Rockwell Automation | Studio 5000 Logix Designer | affected V36.00, 35.00,35.01, 34.00-34.03, 33.00-33.03, 32.00-32.04 and older | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1783.html | [email protected] | www.rockwellautomation.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.