Incorrect Conversion between Numeric Types in NI grpc-device due to missing range checks in CodeGen
Summary
| CVE | CVE-2026-9143 |
|---|---|
| State | PUBLISHED |
| Assigner | NI |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-06-19 14:16:24 UTC |
| Updated | 2026-06-19 14:16:24 UTC |
| Description | There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen. This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions. |
Risk And Classification
Primary CVSS: v4.0 6.3 MEDIUM from [email protected]
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-681 | CWE-681 CWE-681 Incorrect conversion between numeric types
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 6.3 | MEDIUM | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 6.3 | MEDIUM | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Secondary | 3.7 | LOW | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N |
| 3.1 | CNA | CVSS | 3.7 | LOW | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
HighAttack Requirements
NonePrivileges Required
NoneUser Interaction
NoneConfidentiality
NoneIntegrity
LowAvailability
NoneSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
HighPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
NoneIntegrity
LowAvailability
NoneCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | NI | Grpc-device | affected 2.17.0 semver | Not specified |
| CNA | NI | InstrumentStudio | affected 26.3.0 semver | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| github.com/ni/grpc-device/security/advisories/GHSA-rhh6-fvjv-8m84 | [email protected] | github.com | |
| www.ni.com/en/support/security/available-critical-and-security-updates-f... | [email protected] | www.ni.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Sebastián Alba Vives (@Sebasteuo / 0xS4bb1) (en)
There are currently no legacy QID mappings associated with this CVE.