CVE-2026-9266
Summary
| CVE | CVE-2026-9266 |
|---|---|
| State | PUBLISHED |
| Assigner | Moxa |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-06-12 11:16:23 UTC |
| Updated | 2026-06-12 16:06:17 UTC |
| Description | A Missing Required Cryptographic Step vulnerability has been identified in Moxa's embedded Linux firmware for industrial computers and controllers. This vulnerability represents an incomplete remediation of CVE-2026-0714. The firmware introduced TPM2 parameter encryption as a countermeasure against CVE-2026-0714. However, an omission in the authorization session configuration causes the parameter encryption to provide no effective protection. An attacker with invasive physical access to the device can still capture TPM communications on the SPI bus and derive the LUKS disk encryption key in plaintext. While successful exploitation results in full compromise of the encrypted disk volume, the attack requires invasive physical access, including opening the device and attaching external equipment to the SPI bus. Remote exploitation is not possible, and the attack does not affect any downstream systems. |
Risk And Classification
Primary CVSS: v4.0 7 HIGH from [email protected]
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-325 | CWE-325 CWE-325: Missing Cryptographic Step
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 7 | HIGH | CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7 | HIGH | CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CVSS v4.0 Breakdown
Attack Vector
PhysicalAttack Complexity
LowAttack Requirements
NonePrivileges Required
NoneUser Interaction
NoneConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Moxa | UC-1200A Series | affected 1.0 1.4 custom | OS image (MIL3 Secure version) |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.moxa.com/en/support/product-support/security-advisory/mpsa-266240-cve-... | [email protected] | www.moxa.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Cyloq (en)
Additional Advisory Data
Solutions
CNA: Please refer to Moxa's security advisory.
There are currently no legacy QID mappings associated with this CVE.