Besen BS20 EV Charging Station OTA Update Installation improper authorization

Summary

CVECVE-2026-9397
StatePUBLISHED
AssignerVulDB
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-05-24 21:16:32 UTC
Updated2026-05-26 19:57:25 UTC
DescriptionA weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."

Risk And Classification

Primary CVSS: v4.0 8.2 HIGH from [email protected]

CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS: 0.000400000 probability, percentile 0.125420000 (date 2026-05-29)

Problem Types: CWE-266 | CWE-285 | CWE-285 Improper Authorization | CWE-266 Incorrect Privilege Assignment


VersionSourceTypeScoreSeverityVector
4.0[email protected]Secondary8.2HIGHCVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/C...
4.0CNADECLARED9.2CRITICALCVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.1[email protected]Primary8.1HIGHCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
3.1CNADECLARED8.1HIGHCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.0CNADECLARED8.1HIGHCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.0[email protected]Secondary7.6AV:N/AC:H/Au:N/C:C/I:C/A:C
2.0CNADECLARED7.6AV:N/AC:H/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR

CVSS v4.0 Breakdown

Attack Vector
Network
Attack Complexity
High
Attack Requirements
None
Privileges Required
None
User Interaction
None
Confidentiality
High
Integrity
High
Availability
High
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS v3.0 Breakdown

Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Besen BS20 EV Charging Station affected 20260426 Not specified

References

ReferenceSourceLinkTags
vuldb.com/submit/813576 [email protected] vuldb.com
vuldb.com/vuln/365378/cti [email protected] vuldb.com
vuldb.com/vuln/365378 [email protected] vuldb.com
github.com/carfeii/besen [email protected] github.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: carfeii (VulDB User) (en)

CNA: VulDB CNA Team (en)

Additional Advisory Data

SourceTimeEvent
CNA2026-05-24T00:00:00.000ZAdvisory disclosed
CNA2026-05-24T02:00:00.000ZVulDB entry created
CNA2026-05-24T08:24:17.000ZVulDB entry last update
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.