Uncaught exception vulnerability in Suprema's BioStar
Summary
| CVE | CVE-2026-9509 |
|---|---|
| State | PUBLISHED |
| Assigner | INCIBE |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-05-29 13:16:24 UTC |
| Updated | 2026-05-29 13:16:24 UTC |
| Description | An unhandled exception in Suprema BioStar 2 (Server), versions 2.9.8, 2.9.10, and 2.9.11, that allows an unauthenticated remote attacker to cause a denial of service (DoS) by sending HTTP POST requests to the ‘/api/migration’ endpoint. This request triggers a failure that halts critical processes, leaving the system offline until the services or server are manually restarted. As a result, access control readers cease to function, and potential failures may occur in third-party integrations. Since the exploit requires no privileges or user interaction and is trivial to automate, the impact on availability is high, and the effect extends to interconnected systems. |
Risk And Classification
Primary CVSS: v4.0 8.7 HIGH from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-248 | CWE-248 CWE-248 Uncaught exception
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 8.7 | HIGH | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowAttack Requirements
NonePrivileges Required
NoneUser Interaction
NoneConfidentiality
NoneIntegrity
NoneAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Suprema | BioStar 2 Server | affected v2.9.11 custom | Not specified |
| CNA | Suprema | BioStar 2 Server | affected v2.9.10 | Not specified |
| CNA | Suprema | BioStar 2 Server | affected v2.9.8 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-suprema... | [email protected] | www.incibe.es | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Jordi Garcia Ribera (en)
Additional Advisory Data
Solutions
CNA: The vulnerability has been fixed by the Suprema team. We recommend updating to the latest available version.
There are currently no legacy QID mappings associated with this CVE.