Redundancy Module Configuration Tool - Multiple Vulnerabilities

Summary

CVECVE-2026-9634
StatePUBLISHED
AssignerRockwell
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-09-01 14:17:50 UTC
Updated2026-09-01 20:50:01 UTC
DescriptionA security issue exists within the Redundancy Module Configuration Tool. The RMConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non-administrator) users due to incorrect default permissions. If a local attacker places a malicious DLL in such a directory and an administrator subsequently runs the tool, the malicious DLL is loaded into the elevated process and executes with Administrator/SYSTEM privileges.

Risk And Classification

Primary CVSS: v4.0 7 HIGH from [email protected]

CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS: 0.000910000 probability, percentile 0.005500000 (date 2026-09-03)

Problem Types: CWE-276 | CWE-276 CWE-276 Incorrect default permissions


VersionSourceTypeScoreSeverityVector
4.0[email protected]Secondary7HIGHCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C...
4.0CNACVSS7HIGHCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS v4.0 Breakdown

Attack Vector
Local
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
Passive
Confidentiality
High
Integrity
High
Availability
High
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Rockwell Automation Redundancy Module Configuration Tool affected 10.00.00 Not specified

References

ReferenceSourceLinkTags
www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1800.html [email protected] www.rockwellautomation.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report