{"api_version":"1","generated_at":"2026-04-23T05:23:54+00:00","cve":"CVE-1999-1129","urls":{"html":"https://cve.report/CVE-1999-1129","api":"https://cve.report/api/cve/CVE-1999-1129.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-1999-1129","nvd":"https://nvd.nist.gov/vuln/detail/CVE-1999-1129"},"summary":{"title":"CVE-1999-1129","description":"Cisco Catalyst 2900 Virtual LAN (VLAN) switches allow remote attackers to inject 802.1q frames into another VLAN by forging the VLAN identifier in the trunking tag.","state":"PUBLISHED","assigner":"mitre","published_at":"1999-09-01 04:00:00","updated_at":"2025-04-03 01:03:51"},"problem_types":["NVD-CWE-Other","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"7.5","severity":"","vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"http://www.securityfocus.com/bid/615","name":"http://www.securityfocus.com/bid/615","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"],"title":"IEEE 802.1q Unauthorized VLAN Traversal Weakness","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"http://www.securityfocus.com/archive/1/26008","name":"http://www.securityfocus.com/archive/1/26008","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"],"title":"SecurityFocus","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/3294","name":"https://exchange.xforce.ibmcloud.com/vulnerabilities/3294","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"IBM X-Force Exchange","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v8x/eescg8x/aleakyv.htm","name":"http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v8x/eescg8x/aleakyv.htm","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Configuration Examples Related to VLAN Features","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-1999-1129","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-1999-1129","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"1999","cve_id":"1129","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"catalyst_2900_vlan","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"1999","cve_id":"1129","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"ios","cpe6":"11.2\\(8\\)sa5","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-01T17:02:53.702Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"cisco-catalyst-vlan-frames(3294)","tags":["vdb-entry","x_refsource_XF","x_transferred"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/3294"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v8x/eescg8x/aleakyv.htm"},{"name":"19990901 VLAN Security","tags":["mailing-list","x_refsource_BUGTRAQ","x_transferred"],"url":"http://www.securityfocus.com/archive/1/26008"},{"name":"615","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/615"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"1999-09-01T00:00:00.000Z","descriptions":[{"lang":"en","value":"Cisco Catalyst 2900 Virtual LAN (VLAN) switches allow remote attackers to inject 802.1q frames into another VLAN by forging the VLAN identifier in the trunking tag."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-12-18T21:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"cisco-catalyst-vlan-frames(3294)","tags":["vdb-entry","x_refsource_XF"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/3294"},{"tags":["x_refsource_MISC"],"url":"http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v8x/eescg8x/aleakyv.htm"},{"name":"19990901 VLAN Security","tags":["mailing-list","x_refsource_BUGTRAQ"],"url":"http://www.securityfocus.com/archive/1/26008"},{"name":"615","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/615"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-1999-1129","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Cisco Catalyst 2900 Virtual LAN (VLAN) switches allow remote attackers to inject 802.1q frames into another VLAN by forging the VLAN identifier in the trunking tag."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"cisco-catalyst-vlan-frames(3294)","refsource":"XF","url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/3294"},{"name":"http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v8x/eescg8x/aleakyv.htm","refsource":"MISC","url":"http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v8x/eescg8x/aleakyv.htm"},{"name":"19990901 VLAN Security","refsource":"BUGTRAQ","url":"http://www.securityfocus.com/archive/1/26008"},{"name":"615","refsource":"BID","url":"http://www.securityfocus.com/bid/615"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-1999-1129","datePublished":"2001-09-12T04:00:00.000Z","dateReserved":"2001-08-31T00:00:00.000Z","dateUpdated":"2024-08-01T17:02:53.702Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"1999-09-01 04:00:00","lastModifiedDate":"2025-04-03 01:03:51","problem_types":["NVD-CWE-Other","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:ios:11.2\\(8\\)sa5:*:*:*:*:*:*:*","matchCriteriaId":"754F06BF-EB7D-4DAD-BF5D-7DF2619A7499"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:cisco:catalyst_2900_vlan:*:*:*:*:*:*:*:*","matchCriteriaId":"643219DD-5795-48F9-899D-19A27A614F90"}]}]}]},"legacy_mitre":{"record":{"CveYear":"1999","CveId":"1129","Ordinal":"1","Title":"CVE-1999-1129","CVE":"CVE-1999-1129","Year":"1999"},"notes":[{"CveYear":"1999","CveId":"1129","Ordinal":"1","NoteData":"Cisco Catalyst 2900 Virtual LAN (VLAN) switches allow remote attackers to inject 802.1q frames into another VLAN by forging the VLAN identifier in the trunking tag.","Type":"Description","Title":"CVE-1999-1129"},{"CveYear":"1999","CveId":"1129","Ordinal":"2","NoteData":"2001-09-12","Type":"Other","Title":"Published"},{"CveYear":"1999","CveId":"1129","Ordinal":"3","NoteData":"2017-12-18","Type":"Other","Title":"Modified"}]}}}