{"api_version":"1","generated_at":"2026-07-23T06:20:46+00:00","cve":"CVE-2001-1594","urls":{"html":"https://cve.report/CVE-2001-1594","api":"https://cve.report/api/cve/CVE-2001-1594.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2001-1594","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2001-1594"},"summary":{"title":"CVE-2001-1594","description":"GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors.  NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.","state":"PUBLISHED","assigner":"mitre","published_at":"2015-08-04 14:59:00","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-255","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://apps.gehealthcare.com/servlet/ClientServlet/2263784.pdf?DOCCLASS=A&REQ=RAC&DIRECTION=2263784-100&FILENAME=2263784.pdf&FILEREV=5&DOCREV_ORG=5&SUBMIT=+ACCEPT+","name":"http://apps.gehealthcare.com/servlet/ClientServlet/2263784.pdf?DOCCLASS=A&REQ=RAC&DIRECTION=2263784-100&FILENAME=2263784.pdf&FILEREV=5&DOCREV_ORG=5&SUBMIT=+ACCEPT+","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"We're sorry your page cannot be found.","mime":"text/html","httpstatus":"404","archivestatus":"404"},{"url":"http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/","name":"http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Vulnerable Breasts And Brains? Cancer Scan Tech Has Terrible Password Security","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://twitter.com/digitalbond/status/619250429751222277","name":"https://twitter.com/digitalbond/status/619250429751222277","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Dale Peterson on Twitter: \"Funny slide with GE default password word cloud. Go bigguy! #Shakacon http://t.co/t1dcIziQza\"","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02","name":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"GE Medical Devices Vulnerability | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2001-1594","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2001-1594","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2001","cve_id":"1594","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"gehealthcare","cpe5":"entegra_p\\&r","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-08T04:58:11.420Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://apps.gehealthcare.com/servlet/ClientServlet/2263784.pdf?DOCCLASS=A&REQ=RAC&DIRECTION=2263784-100&FILENAME=2263784.pdf&FILEREV=5&DOCREV_ORG=5&SUBMIT=+ACCEPT+"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://twitter.com/digitalbond/status/619250429751222277"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2001-06-17T00:00:00.000Z","descriptions":[{"lang":"en","value":"GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors.  NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-03-27T16:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"http://apps.gehealthcare.com/servlet/ClientServlet/2263784.pdf?DOCCLASS=A&REQ=RAC&DIRECTION=2263784-100&FILENAME=2263784.pdf&FILEREV=5&DOCREV_ORG=5&SUBMIT=+ACCEPT+"},{"tags":["x_refsource_MISC"],"url":"http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/"},{"tags":["x_refsource_MISC"],"url":"https://twitter.com/digitalbond/status/619250429751222277"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2001-1594","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors.  NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://apps.gehealthcare.com/servlet/ClientServlet/2263784.pdf?DOCCLASS=A&REQ=RAC&DIRECTION=2263784-100&FILENAME=2263784.pdf&FILEREV=5&DOCREV_ORG=5&SUBMIT=+ACCEPT+","refsource":"CONFIRM","url":"http://apps.gehealthcare.com/servlet/ClientServlet/2263784.pdf?DOCCLASS=A&REQ=RAC&DIRECTION=2263784-100&FILENAME=2263784.pdf&FILEREV=5&DOCREV_ORG=5&SUBMIT=+ACCEPT+"},{"name":"http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/","refsource":"MISC","url":"http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/"},{"name":"https://twitter.com/digitalbond/status/619250429751222277","refsource":"MISC","url":"https://twitter.com/digitalbond/status/619250429751222277"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2001-1594","datePublished":"2015-08-04T10:00:00.000Z","dateReserved":"2014-09-29T00:00:00.000Z","dateUpdated":"2024-08-08T04:58:11.420Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2015-08-04 14:59:00","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-255","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:gehealthcare:entegra_p\\&r:*:*:*:*:*:*:*:*","matchCriteriaId":"38B4FBF8-59F2-47EF-A662-A43E425625F1"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2001","CveId":"1594","Ordinal":"1","Title":"CVE-2001-1594","CVE":"CVE-2001-1594","Year":"2001"},"notes":[{"CveYear":"2001","CveId":"1594","Ordinal":"1","NoteData":"GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors.  NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.","Type":"Description","Title":"CVE-2001-1594"},{"CveYear":"2001","CveId":"1594","Ordinal":"2","NoteData":"2015-08-04","Type":"Other","Title":"Published"},{"CveYear":"2001","CveId":"1594","Ordinal":"3","NoteData":"2018-03-27","Type":"Other","Title":"Modified"}]}}}