{"api_version":"1","generated_at":"2026-07-23T11:08:42+00:00","cve":"CVE-2008-2474","urls":{"html":"https://cve.report/CVE-2008-2474","api":"https://cve.report/api/cve/CVE-2008-2474.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2008-2474","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2008-2474"},"summary":{"title":"CVE-2008-2474","description":"Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.","state":"PUBLISHED","assigner":"certcc","published_at":"2008-09-29 17:17:29","updated_at":"2026-04-23 00:35:47"},"problem_types":["CWE-119","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://www.kb.cert.org/vuls/id/343971","name":"http://www.kb.cert.org/vuls/id/343971","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["US Government Resource"],"title":"US-CERT Vulnerability Note VU#343971","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://securityreason.com/securityalert/4320","name":"http://securityreason.com/securityalert/4320","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"SecurityReason - C4 Security Advisory - ABB PCU400 4.4-4.6 Remote Buffer Overflow","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/archive/1/496739/100/0/threaded","name":"http://www.securityfocus.com/archive/1/496739/100/0/threaded","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"SecurityFocus","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://secunia.com/advisories/32047","name":"http://secunia.com/advisories/32047","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ABB PCU400 X87 Buffer Overflow Vulnerability - Secunia Advisories - Vulnerability Intelligence - Secunia.com","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.kb.cert.org/vuls/id/CTAR-7JTNRX","name":"http://www.kb.cert.org/vuls/id/CTAR-7JTNRX","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ABB Information for VU#343971","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/31391","name":"http://www.securityfocus.com/bid/31391","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ABB PCU400 'x87' Remote Buffer Overflow Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2008-2474","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2008-2474","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2008","cve_id":"2474","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"abb","cpe5":"pcu400","cpe6":"4.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2008","cve_id":"2474","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"abb","cpe5":"pcu400","cpe6":"4.5","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2008","cve_id":"2474","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"abb","cpe5":"pcu400","cpe6":"4.6","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-07T09:05:30.275Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"20080925 C4 Security Advisory - ABB PCU400 4.4-4.6 Remote Buffer Overflow","tags":["mailing-list","x_refsource_BUGTRAQ","x_transferred"],"url":"http://www.securityfocus.com/archive/1/496739/100/0/threaded"},{"name":"4320","tags":["third-party-advisory","x_refsource_SREASON","x_transferred"],"url":"http://securityreason.com/securityalert/4320"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.kb.cert.org/vuls/id/CTAR-7JTNRX"},{"name":"31391","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/31391"},{"name":"32047","tags":["third-party-advisory","x_refsource_SECUNIA","x_transferred"],"url":"http://secunia.com/advisories/32047"},{"name":"VU#343971","tags":["third-party-advisory","x_refsource_CERT-VN","x_transferred"],"url":"http://www.kb.cert.org/vuls/id/343971"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2008-09-25T00:00:00.000Z","descriptions":[{"lang":"en","value":"Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-10-11T19:57:01.000Z","orgId":"37e5125f-f79b-445b-8fad-9564f167944b","shortName":"certcc"},"references":[{"name":"20080925 C4 Security Advisory - ABB PCU400 4.4-4.6 Remote Buffer Overflow","tags":["mailing-list","x_refsource_BUGTRAQ"],"url":"http://www.securityfocus.com/archive/1/496739/100/0/threaded"},{"name":"4320","tags":["third-party-advisory","x_refsource_SREASON"],"url":"http://securityreason.com/securityalert/4320"},{"tags":["x_refsource_CONFIRM"],"url":"http://www.kb.cert.org/vuls/id/CTAR-7JTNRX"},{"name":"31391","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/31391"},{"name":"32047","tags":["third-party-advisory","x_refsource_SECUNIA"],"url":"http://secunia.com/advisories/32047"},{"name":"VU#343971","tags":["third-party-advisory","x_refsource_CERT-VN"],"url":"http://www.kb.cert.org/vuls/id/343971"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cert@cert.org","ID":"CVE-2008-2474","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"20080925 C4 Security Advisory - ABB PCU400 4.4-4.6 Remote Buffer Overflow","refsource":"BUGTRAQ","url":"http://www.securityfocus.com/archive/1/496739/100/0/threaded"},{"name":"4320","refsource":"SREASON","url":"http://securityreason.com/securityalert/4320"},{"name":"http://www.kb.cert.org/vuls/id/CTAR-7JTNRX","refsource":"CONFIRM","url":"http://www.kb.cert.org/vuls/id/CTAR-7JTNRX"},{"name":"31391","refsource":"BID","url":"http://www.securityfocus.com/bid/31391"},{"name":"32047","refsource":"SECUNIA","url":"http://secunia.com/advisories/32047"},{"name":"VU#343971","refsource":"CERT-VN","url":"http://www.kb.cert.org/vuls/id/343971"}]}}}},"cveMetadata":{"assignerOrgId":"37e5125f-f79b-445b-8fad-9564f167944b","assignerShortName":"certcc","cveId":"CVE-2008-2474","datePublished":"2008-09-29T17:00:00.000Z","dateReserved":"2008-05-28T00:00:00.000Z","dateUpdated":"2024-08-07T09:05:30.275Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2008-09-29 17:17:29","lastModifiedDate":"2026-04-23 00:35:47","problem_types":["CWE-119","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":true,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:abb:pcu400:4.4:*:*:*:*:*:*:*","matchCriteriaId":"053989DE-274C-4000-83E2-3B6BB13C72A3"},{"vulnerable":true,"criteria":"cpe:2.3:h:abb:pcu400:4.5:*:*:*:*:*:*:*","matchCriteriaId":"7F189832-AAE9-467D-ACC0-F1DD81C1DA5E"},{"vulnerable":true,"criteria":"cpe:2.3:h:abb:pcu400:4.6:*:*:*:*:*:*:*","matchCriteriaId":"50B1D03E-E73B-4759-A841-CEBE6CA7F4F8"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2008","CveId":"2474","Ordinal":"1","Title":"CVE-2008-2474","CVE":"CVE-2008-2474","Year":"2008"},"notes":[{"CveYear":"2008","CveId":"2474","Ordinal":"1","NoteData":"Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.","Type":"Description","Title":"CVE-2008-2474"},{"CveYear":"2008","CveId":"2474","Ordinal":"2","NoteData":"2008-09-29","Type":"Other","Title":"Published"},{"CveYear":"2008","CveId":"2474","Ordinal":"3","NoteData":"2018-10-11","Type":"Other","Title":"Modified"}]}}}