{"api_version":"1","generated_at":"2026-07-23T09:56:58+00:00","cve":"CVE-2010-2772","urls":{"html":"https://cve.report/CVE-2010-2772","api":"https://cve.report/api/cve/CVE-2010-2772.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2010-2772","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2010-2772"},"summary":{"title":"CVE-2010-2772","description":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.","state":"PUBLISHED","assigner":"mitre","published_at":"2010-07-22 05:43:58","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-798","n/a"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.9","severity":"","vector":"AV:L/AC:M/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:C/I:C/A:C","baseScore":6.9,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","name":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Press/Media Coverage"],"title":"Siemens warns users: Don't change passwords after worm attack | Security Central - InfoWorld","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/","name":"http://www.wired.com/threatlevel/2010/07/siemens-scada/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Press/Media Coverage","Third Party Advisory"],"title":"SCADA System’s Hard-Coded Password Circulated Online for Years | Threat Level | Wired.com","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","name":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Issue Tracking"],"title":"Wilders Security Forums - View Single Post - Rootkit.TmpHider","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","name":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Press/Media Coverage"],"title":"Experts Warn of New Windows Shortcut Flaw —  Krebs on Security","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","name":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"],"title":"Wincc Database problem - Siemens Industry IA/DT/BT Service & Support - Technical Forum (Guest)","mime":"text/html","httpstatus":"403","archivestatus":"200"},{"url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","name":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Press/Media Coverage"],"title":"New 'weaponized' virus targets industrial secrets | Security Central - InfoWorld","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587","name":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"IBM X-Force Exchange","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.f-secure.com/weblog/archives/00001987.html","name":"http://www.f-secure.com/weblog/archives/00001987.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"News from the Lab Archive : January 2004 to September 2015","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","name":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link","Vendor Advisory"],"title":"403 Forbidden","mime":"text/html","httpstatus":"403","archivestatus":"403"},{"url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","name":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Not Applicable"],"title":"Siemens Industry IA/DT/BT Service&Support - Automation Service, Automation Support, Simatic Service, Simatic Support, Technical Support, Technical Consulting","mime":"text/html","httpstatus":"403","archivestatus":"200"},{"url":"http://secunia.com/advisories/40682","name":"http://secunia.com/advisories/40682","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"],"title":"Siemens SIMATIC WinCC Undocumented Database User Account - Advisories - Community","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.vupen.com/english/advisories/2010/1893","name":"http://www.vupen.com/english/advisories/2010/1893","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"],"title":"Webmail : Solution de messagerie professionnelle - OVHcloud- OVH","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/41753","name":"http://www.securityfocus.com/bid/41753","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link","Third Party Advisory","VDB Entry"],"title":"Siemens SIMATIC WinCC Default Password Security Bypass Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","name":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Siemens WinCC Insecure SQL Server Authentication | CISA","mime":"text/html","httpstatus":"200","archivestatus":"403"},{"url":"https://www.cve.org/CVERecord?id=CVE-2010-2772","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2010-2772","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"6.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"6.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"7.0","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"7.0","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"7.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"7.1","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"6.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2010","cve_id":"2772","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-07T02:46:48.161Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"simatic-wincc-default-password(60587)","tags":["vdb-entry","x_refsource_XF","x_transferred"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.f-secure.com/weblog/archives/00001987.html"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1"},{"name":"ADV-2010-1893","tags":["vdb-entry","x_refsource_VUPEN","x_transferred"],"url":"http://www.vupen.com/english/advisories/2010/1893"},{"name":"40682","tags":["third-party-advisory","x_refsource_SECUNIA","x_transferred"],"url":"http://secunia.com/advisories/40682"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"},{"name":"41753","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/41753"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2010-07-16T00:00:00.000Z","descriptions":[{"lang":"en","value":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-08-16T14:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"simatic-wincc-default-password(60587)","tags":["vdb-entry","x_refsource_XF"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"},{"tags":["x_refsource_MISC"],"url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"},{"tags":["x_refsource_CONFIRM"],"url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c"},{"tags":["x_refsource_MISC"],"url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"},{"tags":["x_refsource_MISC"],"url":"http://www.f-secure.com/weblog/archives/00001987.html"},{"tags":["x_refsource_MISC"],"url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1"},{"name":"ADV-2010-1893","tags":["vdb-entry","x_refsource_VUPEN"],"url":"http://www.vupen.com/english/advisories/2010/1893"},{"name":"40682","tags":["third-party-advisory","x_refsource_SECUNIA"],"url":"http://secunia.com/advisories/40682"},{"tags":["x_refsource_MISC"],"url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"},{"tags":["x_refsource_CONFIRM"],"url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"},{"name":"41753","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/41753"},{"tags":["x_refsource_MISC"],"url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"},{"tags":["x_refsource_MISC"],"url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22"},{"tags":["x_refsource_MISC"],"url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2010-2772","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"simatic-wincc-default-password(60587)","refsource":"XF","url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"},{"name":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","refsource":"MISC","url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"},{"name":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","refsource":"CONFIRM","url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c"},{"name":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","refsource":"MISC","url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"},{"name":"http://www.f-secure.com/weblog/archives/00001987.html","refsource":"MISC","url":"http://www.f-secure.com/weblog/archives/00001987.html"},{"name":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","refsource":"MISC","url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1"},{"name":"ADV-2010-1893","refsource":"VUPEN","url":"http://www.vupen.com/english/advisories/2010/1893"},{"name":"40682","refsource":"SECUNIA","url":"http://secunia.com/advisories/40682"},{"name":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","refsource":"MISC","url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"},{"name":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","refsource":"CONFIRM","url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"},{"name":"41753","refsource":"BID","url":"http://www.securityfocus.com/bid/41753"},{"name":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","refsource":"MISC","url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"},{"name":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","refsource":"MISC","url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22"},{"name":"http://www.wired.com/threatlevel/2010/07/siemens-scada/","refsource":"MISC","url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2010-2772","datePublished":"2010-07-22T10:00:00.000Z","dateReserved":"2010-07-21T00:00:00.000Z","dateUpdated":"2024-08-07T02:46:48.161Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2010-07-22 05:43:58","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-798","n/a"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:C/I:C/A:C","baseScore":6.9,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"MEDIUM","exploitabilityScore":3.4,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":true,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:6.2:*:*:*:*:*:*:*","matchCriteriaId":"9BD0EB37-CFA4-49AE-A952-1A4E2E2EE998"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*","matchCriteriaId":"3CF84FC5-9450-47B7-A4F0-99361C528C00"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:6.0:*:*:*:*:*:*:*","matchCriteriaId":"963E0E16-2A77-45C8-8708-46B4158C40D0"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:6.1:*:*:*:*:*:*:*","matchCriteriaId":"2C026414-5F0C-48E7-A93D-12E2E33AB6CB"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:7.0:-:*:*:*:*:*:*","matchCriteriaId":"BD419DE7-CB43-42E7-ACCC-82EA4913E8D2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:7.0:sp1:*:*:*:*:*:*","matchCriteriaId":"036B082A-1B48-4BA0-A915-4344C70E430D"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:7.1:*:*:*:*:*:*:*","matchCriteriaId":"D7885AE5-023B-45BC-8E4A-CF796B5757C2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*","matchCriteriaId":"BE258BF2-AD82-401C-B020-08A22A549A25"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2010","CveId":"2772","Ordinal":"1","Title":"CVE-2010-2772","CVE":"CVE-2010-2772","Year":"2010"},"notes":[{"CveYear":"2010","CveId":"2772","Ordinal":"1","NoteData":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.","Type":"Description","Title":"CVE-2010-2772"},{"CveYear":"2010","CveId":"2772","Ordinal":"2","NoteData":"2010-07-22","Type":"Other","Title":"Published"},{"CveYear":"2010","CveId":"2772","Ordinal":"3","NoteData":"2017-08-16","Type":"Other","Title":"Modified"}]}}}