{"api_version":"1","generated_at":"2026-07-23T04:22:24+00:00","cve":"CVE-2011-4036","urls":{"html":"https://cve.report/CVE-2011-4036","api":"https://cve.report/api/cve/CVE-2011-4036.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2011-4036","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2011-4036"},"summary":{"title":"CVE-2011-4036","description":"Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.","state":"PUBLISHED","assigner":"certcc","published_at":"2011-12-02 11:55:05","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-22","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"5","severity":"","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"}}],"references":[{"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf","name":"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["US Government Resource"],"title":"404 - File Not Found | CISA","mime":"application/pdf","httpstatus":"404","archivestatus":"200"},{"url":"http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695","name":"http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Vulnerability in Historian","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page","name":"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"SCADA Global Support Extranet","mime":"text/html","httpstatus":"-1","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2011-4036","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2011-4036","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citecthistorian","cpe6":"4.20","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"4.30","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citecthistorian","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citectscada_reports","cpe6":"4.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"4.10","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citectscada_reports","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"vijeo_historian","cpe6":"4.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"vijeo_historian","cpe6":"4.10","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"vijeo_historian","cpe6":"4.20","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2011","cve_id":"4036","vulnerable":"1","versionEndIncluding":"4.30","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"vijeo_historian","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T23:53:32.604Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2011-12-02T11:00:00.000Z","orgId":"37e5125f-f79b-445b-8fad-9564f167944b","shortName":"certcc"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"},{"tags":["x_refsource_MISC"],"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"},{"tags":["x_refsource_CONFIRM"],"url":"http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cert@cert.org","ID":"CVE-2011-4036","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page","refsource":"CONFIRM","url":"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"},{"name":"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf","refsource":"MISC","url":"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"},{"name":"http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695","refsource":"CONFIRM","url":"http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695"}]}}}},"cveMetadata":{"assignerOrgId":"37e5125f-f79b-445b-8fad-9564f167944b","assignerShortName":"certcc","cveId":"CVE-2011-4036","datePublished":"2011-12-02T11:00:00.000Z","dateReserved":"2011-10-13T00:00:00.000Z","dateUpdated":"2024-09-16T18:13:14.310Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2011-12-02 11:55:05","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-22","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*","versionEndIncluding":"4.30","matchCriteriaId":"FA173AD2-52AF-4401-9A29-757B68168B4D"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*","matchCriteriaId":"00E3E11B-E433-4D89-9525-8159CEC30DC0"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*","matchCriteriaId":"2788D1E5-206A-4AC8-AA28-65E5EE268B59"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*","matchCriteriaId":"99B88BED-7F2F-4F89-9BD1-B7EDC1608531"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*","versionEndIncluding":"4.30","matchCriteriaId":"859A64AD-1FB2-4A7C-AE4D-26951FC050F9"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*","matchCriteriaId":"B491E331-B533-4E09-966E-45A3BE724C5A"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*","versionEndIncluding":"4.10","matchCriteriaId":"106C6198-C341-4B10-8788-A8FA51F137F1"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*","matchCriteriaId":"38765B0B-9C09-4BC0-9E50-D0C6E8969A77"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2011","CveId":"4036","Ordinal":"1","Title":"CVE-2011-4036","CVE":"CVE-2011-4036","Year":"2011"},"notes":[{"CveYear":"2011","CveId":"4036","Ordinal":"1","NoteData":"Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.","Type":"Description","Title":"CVE-2011-4036"},{"CveYear":"2011","CveId":"4036","Ordinal":"2","NoteData":"2011-12-02","Type":"Other","Title":"Published"}]}}}