{"api_version":"1","generated_at":"2026-05-15T09:16:14+00:00","cve":"CVE-2012-0254","urls":{"html":"https://cve.report/CVE-2012-0254","api":"https://cve.report/api/cve/CVE-2012-0254.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2012-0254","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2012-0254"},"summary":{"title":"CVE-2012-0254","description":"Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors.","state":"PUBLISHED","assigner":"certcc","published_at":"2012-09-08 10:28:19","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-787","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"7.5","severity":"","vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx","name":"https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"All Notifications","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf","name":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"404 - File Not Found | CISA","mime":"application/pdf","httpstatus":"404","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2012-0254","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2012-0254","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"enterprise_building_manager","cpe6":"r400","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"enterprise_building_manager","cpe6":"r410.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"experion","cpe6":"r200","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"experion","cpe6":"r300","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"experion","cpe6":"r310","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"experion","cpe6":"r400.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"254","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"honeywell","cpe5":"symmetre","cpe6":"r410.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T18:16:20.019Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2012-09-08T10:00:00.000Z","orgId":"37e5125f-f79b-445b-8fad-9564f167944b","shortName":"certcc"},"references":[{"tags":["x_refsource_MISC"],"url":"https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx"},{"tags":["x_refsource_MISC"],"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cert@cert.org","ID":"CVE-2012-0254","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx","refsource":"MISC","url":"https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx"},{"name":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf","refsource":"MISC","url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf"}]}}}},"cveMetadata":{"assignerOrgId":"37e5125f-f79b-445b-8fad-9564f167944b","assignerShortName":"certcc","cveId":"CVE-2012-0254","datePublished":"2012-09-08T10:00:00.000Z","dateReserved":"2011-12-21T00:00:00.000Z","dateUpdated":"2024-09-16T17:49:22.368Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2012-09-08 10:28:19","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-787","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:enterprise_building_manager:r400:*:*:*:*:*:*:*","matchCriteriaId":"A32232BC-3D81-41AB-BF19-B2305E3750D1"},{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:enterprise_building_manager:r410.1:*:*:*:*:*:*:*","matchCriteriaId":"3A1AEB6F-CDEE-448D-AB57-E479B12E0ABB"},{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:experion:r200:*:*:*:*:*:*:*","matchCriteriaId":"17667B2A-3A9B-4045-B393-4770889B43C3"},{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:experion:r300:*:*:*:*:*:*:*","matchCriteriaId":"7F1F6FF0-8195-4B3C-9376-197F6E114F1B"},{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:experion:r310:*:*:*:*:*:*:*","matchCriteriaId":"B22DEAFD-AD38-449A-BA19-4B71D481C635"},{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:experion:r400.0:*:*:*:*:*:*:*","matchCriteriaId":"57EEB7F4-4E1F-46BD-8650-6F1AA1BD5D2D"},{"vulnerable":true,"criteria":"cpe:2.3:a:honeywell:symmetre:r410.1:*:*:*:*:*:*:*","matchCriteriaId":"157923CF-52A2-4F5E-B5DA-26E875CBA4B8"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2012","CveId":"254","Ordinal":"1","Title":"CVE-2012-0254","CVE":"CVE-2012-0254","Year":"2012"},"notes":[{"CveYear":"2012","CveId":"254","Ordinal":"1","NoteData":"Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors.","Type":"Description","Title":"CVE-2012-0254"},{"CveYear":"2012","CveId":"254","Ordinal":"2","NoteData":"2012-09-08","Type":"Other","Title":"Published"}]}}}