{"api_version":"1","generated_at":"2026-04-23T04:09:46+00:00","cve":"CVE-2012-1802","urls":{"html":"https://cve.report/CVE-2012-1802","api":"https://cve.report/api/cve/CVE-2012-1802.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2012-1802","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2012-1802"},"summary":{"title":"CVE-2012-1802","description":"Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.","state":"PUBLIC","assigner":"cert@cert.org","published_at":"2012-04-18 10:33:00","updated_at":"2012-11-20 04:44:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf","name":"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Siemens","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"http://osvdb.org/81032","name":"81032","refsource":"OSVDB","tags":[],"title":"","mime":"","httpstatus":"-1","archivestatus":"0"},{"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf","name":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf","refsource":"MISC","tags":["US Government Resource"],"title":"404 - File Not Found | CISA","mime":"application/pdf","httpstatus":"404","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2012-1802","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2012-1802","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x-300","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x-300","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x-300eec","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x-300eec","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300eec_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300eec_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"3.7.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300eec_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"2.3.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.0.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.3.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.5.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"2.3.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.0.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.3.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"3.5.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"3.7.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x-300_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x308-2m","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x308-2m","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"3.1.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"3.5.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"3.1.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"3.5.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"3.7.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x308-2m_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x414-3e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_x414-3e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"1.2.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.1.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.3.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.3.3","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.0.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.0.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.4.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"1.2.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.1.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.3.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"2.3.3","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.0.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.0.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"3.4.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"3.7.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_x414-3e_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_xr-300","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_xr-300","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_xr-300_firmware","cpe6":"3.1.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_xr-300_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_xr-300_firmware","cpe6":"3.1.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_xr-300_firmware","cpe6":"3.5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2012","cve_id":"1802","vulnerable":"1","versionEndIncluding":"3.7.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"scalance_xr-300_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cert@cert.org","ID":"CVE-2012-1802","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"81032","refsource":"OSVDB","url":"http://osvdb.org/81032"},{"name":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf","refsource":"MISC","url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"},{"name":"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf","refsource":"CONFIRM","url":"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"}]}},"nvd":{"publishedDate":"2012-04-18 10:33:00","lastModifiedDate":"2012-11-20 04:44:00","problem_types":["CWE-119"],"metrics":{"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE","baseScore":7.8},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"3.7.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.3:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.2:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.3.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.4.0:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:h:siemens:scalance_x414-3e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"3.7.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.1.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.2:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300eec_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"3.7.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300eec_firmware:3.5.0:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"3.7.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_xr-300_firmware:3.1.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_xr-300_firmware:3.5.0:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"3.7.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:2.2.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:2.3.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:3.0.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:3.3.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2012","CveId":"1802","Ordinal":"54479","Title":"CVE-2012-1802","CVE":"CVE-2012-1802","Year":"2012"},"notes":[{"CveYear":"2012","CveId":"1802","Ordinal":"1","NoteData":"Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.","Type":"Description","Title":null},{"CveYear":"2012","CveId":"1802","Ordinal":"2","NoteData":"2012-04-18","Type":"Other","Title":"Published"},{"CveYear":"2012","CveId":"1802","Ordinal":"3","NoteData":"2012-11-20","Type":"Other","Title":"Modified"}]}}}