{"api_version":"1","generated_at":"2026-07-23T07:16:44+00:00","cve":"CVE-2013-0657","urls":{"html":"https://cve.report/CVE-2013-0657","api":"https://cve.report/api/cve/CVE-2013-0657.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2013-0657","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2013-0657"},"summary":{"title":"CVE-2013-0657","description":"Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.","state":"PUBLISHED","assigner":"icscert","published_at":"2013-01-21 16:55:01","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-119","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf","name":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","US Government Resource"],"title":"Schneider Electric IGSS Buffer Overflow | ICS-CERT","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip","name":"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch"],"title":"","mime":"application/zip","httpstatus":"200","archivestatus":"200"},{"url":"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip","name":"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch"],"title":"","mime":"application/zip","httpstatus":"200","archivestatus":"200"},{"url":"https://www.exploit-db.com/exploits/45218/","name":"https://www.exploit-db.com/exploits/45218/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"SEIG SCADA System 9 - Remote Code Execution - Windows_x86 remote Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2013-0657","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2013-0657","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2013","cve_id":"657","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"9.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"657","vulnerable":"1","versionEndIncluding":"10.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T14:33:05.720Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf"},{"name":"45218","tags":["exploit","x_refsource_EXPLOIT-DB","x_transferred"],"url":"https://www.exploit-db.com/exploits/45218/"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2013-01-18T00:00:00.000Z","descriptions":[{"lang":"en","value":"Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-08-21T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf"},{"name":"45218","tags":["exploit","x_refsource_EXPLOIT-DB"],"url":"https://www.exploit-db.com/exploits/45218/"},{"tags":["x_refsource_CONFIRM"],"url":"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip"},{"tags":["x_refsource_CONFIRM"],"url":"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2013-0657","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf","refsource":"MISC","url":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf"},{"name":"45218","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/45218/"},{"name":"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip","refsource":"CONFIRM","url":"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip"},{"name":"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip","refsource":"CONFIRM","url":"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2013-0657","datePublished":"2013-01-21T16:00:00.000Z","dateReserved":"2012-12-19T00:00:00.000Z","dateUpdated":"2024-08-06T14:33:05.720Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2013-01-21 16:55:01","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-119","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionEndIncluding":"10.0","matchCriteriaId":"09179F1F-9640-488B-BA2E-138804055F4F"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:9.0:*:*:*:*:*:*:*","matchCriteriaId":"D8C7660B-F963-44F7-8E49-8ADF9D04CBCB"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2013","CveId":"657","Ordinal":"1","Title":"CVE-2013-0657","CVE":"CVE-2013-0657","Year":"2013"},"notes":[{"CveYear":"2013","CveId":"657","Ordinal":"1","NoteData":"Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.","Type":"Description","Title":"CVE-2013-0657"},{"CveYear":"2013","CveId":"657","Ordinal":"2","NoteData":"2013-01-21","Type":"Other","Title":"Published"},{"CveYear":"2013","CveId":"657","Ordinal":"3","NoteData":"2018-08-21","Type":"Other","Title":"Modified"}]}}}