{"api_version":"1","generated_at":"2026-07-23T08:29:17+00:00","cve":"CVE-2013-0663","urls":{"html":"https://cve.report/CVE-2013-0663","api":"https://cve.report/api/cve/CVE-2013-0663.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2013-0663","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2013-0663"},"summary":{"title":"CVE-2013-0663","description":"Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.","state":"PUBLISHED","assigner":"icscert","published_at":"2013-04-04 11:58:48","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-352","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.8","severity":"","vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf","name":"http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["US Government Resource"],"title":"404 - File Not Found | CISA","mime":"application/pdf","httpstatus":"404","archivestatus":"200"},{"url":"http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper","name":"http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Product Documentation & Software downloads | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.exploit-db.com/exploits/44678/","name":"https://www.exploit-db.com/exploits/44678/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Schneider Electric PLCs - Cross-Site Request Forgery - Windows webapps Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/","name":"http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Documents & Downloads","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2013-0663","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2013-0663","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m340","cpe6":"bmxnoc0401","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m340","cpe6":"bmxnoe0100x","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m340","cpe6":"bmxnoe011xx","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_premium","cpe6":"tsxety4103","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_premium","cpe6":"tsxety5103","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_premium","cpe6":"tsxwmy100","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_quantum_plc","cpe6":"140noe77101","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_quantum_plc","cpe6":"140noe77111","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"663","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_quantum_plc","cpe6":"140nwm10000","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2013-0663","qid":"590485","title":"Schneider Electric PLCs (Update B) Multiple Vulnerabilities (ICSA-13-077-01B)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T14:33:05.456Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"44678","tags":["exploit","x_refsource_EXPLOIT-DB","x_transferred"],"url":"https://www.exploit-db.com/exploits/44678/"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2013-01-23T00:00:00.000Z","descriptions":[{"lang":"en","value":"Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-05-23T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"name":"44678","tags":["exploit","x_refsource_EXPLOIT-DB"],"url":"https://www.exploit-db.com/exploits/44678/"},{"tags":["x_refsource_CONFIRM"],"url":"http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"},{"tags":["x_refsource_CONFIRM"],"url":"http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper"},{"tags":["x_refsource_MISC"],"url":"http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2013-0663","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"44678","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/44678/"},{"name":"http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/","refsource":"CONFIRM","url":"http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"},{"name":"http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper","refsource":"CONFIRM","url":"http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper"},{"name":"http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf","refsource":"MISC","url":"http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2013-0663","datePublished":"2013-04-04T10:00:00.000Z","dateReserved":"2012-12-19T00:00:00.000Z","dateUpdated":"2024-08-06T14:33:05.456Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2013-04-04 11:58:48","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-352","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_quantum_plc:140noe77101:*:*:*:*:*:*:*","matchCriteriaId":"18705050-B954-4AB9-A8D0-BDCB09A9839A"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_quantum_plc:140noe77111:*:*:*:*:*:*:*","matchCriteriaId":"56FB594F-638A-4E8B-9072-475E64CDE999"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_quantum_plc:140nwm10000:*:*:*:*:*:*:*","matchCriteriaId":"AD53FEBF-FF81-4563-B80C-CE67ABDA233B"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_m340:bmxnoc0401:*:*:*:*:*:*:*","matchCriteriaId":"00C02342-50B0-4883-9430-9CAB7968081B"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_m340:bmxnoe011xx:*:*:*:*:*:*:*","matchCriteriaId":"21E85599-1298-4B8C-8255-42D165F905F4"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_m340:bmxnoe0100x:*:*:*:*:*:*:*","matchCriteriaId":"1F41B43D-038F-4775-A1BB-486918806E7E"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_premium:tsxety4103:*:*:*:*:*:*:*","matchCriteriaId":"FEEA7CF9-59A9-4B40-9E20-F179D40815C9"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_premium:tsxety5103:*:*:*:*:*:*:*","matchCriteriaId":"D7579763-6663-41F7-A162-5FEBA9A9CE70"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:modicon_premium:tsxwmy100:*:*:*:*:*:*:*","matchCriteriaId":"42C34DAA-D856-4E59-A98F-2DF47E600612"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2013","CveId":"663","Ordinal":"1","Title":"CVE-2013-0663","CVE":"CVE-2013-0663","Year":"2013"},"notes":[{"CveYear":"2013","CveId":"663","Ordinal":"1","NoteData":"Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.","Type":"Description","Title":"CVE-2013-0663"},{"CveYear":"2013","CveId":"663","Ordinal":"2","NoteData":"2013-04-04","Type":"Other","Title":"Published"},{"CveYear":"2013","CveId":"663","Ordinal":"3","NoteData":"2018-05-23","Type":"Other","Title":"Modified"}]}}}