{"api_version":"1","generated_at":"2026-04-23T14:42:22+00:00","cve":"CVE-2013-3075","urls":{"html":"https://cve.report/CVE-2013-3075","api":"https://cve.report/api/cve/CVE-2013-3075.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2013-3075","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2013-3075"},"summary":{"title":"CVE-2013-3075","description":"Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2013-04-19 11:44:00","updated_at":"2013-05-15 04:00:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"http://www.exploit-db.com/exploits/24886/","name":"24886","refsource":"EXPLOIT-DB","tags":["Exploit"],"title":"Mitsubishi MX ActiveX Component v3 (ActUWzd.dll (WzTitle)) - Remote Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2013-3075","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2013-3075","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2013","cve_id":"3075","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishi-automation","cpe5":"mitsubishi_mx_component","cpe6":"3","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"3075","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishi-automation","cpe5":"mitsubishi_mx_component","cpe6":"3","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"3075","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citectfacilities","cpe6":"7.10","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"3075","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citectfacilities","cpe6":"7.10","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"3075","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citectscada","cpe6":"7.10","cpe7":"r1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"3075","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citectscada","cpe6":"7.10","cpe7":"r1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2013-3075","qid":"590565","title":"Mitsubishi Electric Automation MX Component V3 ActiveX Buffer Overflow Vulnerability (ICSA-13-140-01)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2013-3075","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"24886","refsource":"EXPLOIT-DB","url":"http://www.exploit-db.com/exploits/24886/"}]}},"nvd":{"publishedDate":"2013-04-19 11:44:00","lastModifiedDate":"2013-05-15 04:00:00","problem_types":["CWE-119"],"metrics":{"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":10},"severity":"HIGH","exploitabilityScore":10,"impactScore":10,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:mitsubishi-automation:mitsubishi_mx_component:3:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:citectfacilities:7.10:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:citectscada:7.10:r1:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2013","CveId":"3075","Ordinal":"62719","Title":"CVE-2013-3075","CVE":"CVE-2013-3075","Year":"2013"},"notes":[{"CveYear":"2013","CveId":"3075","Ordinal":"1","NoteData":"Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.","Type":"Description","Title":null},{"CveYear":"2013","CveId":"3075","Ordinal":"2","NoteData":"2013-04-19","Type":"Other","Title":"Published"}]}}}