{"api_version":"1","generated_at":"2026-06-20T21:23:22+00:00","cve":"CVE-2013-5022","urls":{"html":"https://cve.report/CVE-2013-5022","api":"https://cve.report/api/cve/CVE-2013-5022.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2013-5022","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2013-5022"},"summary":{"title":"CVE-2013-5022","description":"Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.","state":"PUBLISHED","assigner":"mitre","published_at":"2013-08-06 20:55:05","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-22","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument","name":"http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"How Does NI Security Update 67L8L0QW for cw3dgrph.ocx Affect Me? - National Instruments","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument","name":"http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"What Is the Nature of Software Vulnerability NI-64BG6SWQ-2? - National Instruments","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument","name":"http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"],"title":"How Do The NI Q2 2013 Security Updates Affect Me? - National Instruments","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2013-5022","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2013-5022","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2013","cve_id":"5022","vulnerable":"1","versionEndIncluding":"2012","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ni","cpe5":"labview","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"5022","vulnerable":"1","versionEndIncluding":"2012","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ni","cpe5":"labwindows","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"5022","vulnerable":"1","versionEndIncluding":"2013","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ni","cpe5":"measurementstudio","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2013","cve_id":"5022","vulnerable":"1","versionEndIncluding":"2012","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ni","cpe5":"teststand","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T16:59:41.206Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2013-05-20T00:00:00.000Z","descriptions":[{"lang":"en","value":"Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2013-09-17T09:00:00.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"},{"tags":["x_refsource_CONFIRM"],"url":"http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"},{"tags":["x_refsource_CONFIRM"],"url":"http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2013-5022","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument","refsource":"CONFIRM","url":"http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"},{"name":"http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument","refsource":"CONFIRM","url":"http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"},{"name":"http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument","refsource":"CONFIRM","url":"http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2013-5022","datePublished":"2013-08-06T18:00:00.000Z","dateReserved":"2013-07-31T00:00:00.000Z","dateUpdated":"2024-08-06T16:59:41.206Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2013-08-06 20:55:05","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-22","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*","versionEndIncluding":"2012","matchCriteriaId":"3815CFE4-4E5E-44BB-B206-520C39DE3674"},{"vulnerable":true,"criteria":"cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*","versionEndIncluding":"2012","matchCriteriaId":"EC46A398-C8F3-49B2-BDDE-20DEA80EC941"},{"vulnerable":true,"criteria":"cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*","versionEndIncluding":"2013","matchCriteriaId":"A12E5F42-B2FC-48F4-8D04-5B59A3869461"},{"vulnerable":true,"criteria":"cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*","versionEndIncluding":"2012","matchCriteriaId":"68051582-D70F-4B32-A9F9-64A5E33CB481"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2013","CveId":"5022","Ordinal":"1","Title":"CVE-2013-5022","CVE":"CVE-2013-5022","Year":"2013"},"notes":[{"CveYear":"2013","CveId":"5022","Ordinal":"1","NoteData":"Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.","Type":"Description","Title":"CVE-2013-5022"},{"CveYear":"2013","CveId":"5022","Ordinal":"2","NoteData":"2013-08-06","Type":"Other","Title":"Published"},{"CveYear":"2013","CveId":"5022","Ordinal":"3","NoteData":"2013-09-17","Type":"Other","Title":"Modified"}]}}}