{"api_version":"1","generated_at":"2026-07-23T11:56:43+00:00","cve":"CVE-2014-1201","urls":{"html":"https://cve.report/CVE-2014-1201","api":"https://cve.report/api/cve/CVE-2014-1201.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2014-1201","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2014-1201"},"summary":{"title":"CVE-2014-1201","description":"Buffer overflow in the INetViewX ActiveX control in the Lorex Edge LH310 and Edge+ LH320 series with firmware 7-35-28-1B26E, Edge2 LH330 series with firmware 11.17.38-33_1D97A, and Edge3 LH340 series with firmware 11.19.85_1FE3A allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long string in the HTTP_PORT parameter.","state":"PUBLISHED","assigner":"mitre","published_at":"2014-01-15 16:08:18","updated_at":"2026-04-29 01:13:23"},"problem_types":["CWE-119","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://www.securityfocus.com/archive/1/530739/100/0/threaded","name":"http://www.securityfocus.com/archive/1/530739/100/0/threaded","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"SecurityFocus","mime":"text/html","httpstatus":"-1","archivestatus":"200"},{"url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-testcase.html","name":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-testcase.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Page not found · GitHub · GitHub","mime":"text/html","httpstatus":"404","archivestatus":"404"},{"url":"http://osvdb.org/101903","name":"http://osvdb.org/101903","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"-1","archivestatus":"0"},{"url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-report.txt","name":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-report.txt","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Page not found · GitHub · GitHub","mime":"text/html","httpstatus":"404","archivestatus":"404"},{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/90223","name":"https://exchange.xforce.ibmcloud.com/vulnerabilities/90223","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"IBM X-Force Exchange","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2014-1201","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2014-1201","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lorextechnology","cpe5":"edge","cpe6":"lh310","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lorextechnology","cpe5":"edge2","cpe6":"lh330","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lorextechnology","cpe5":"edge3","cpe6":"lh340","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lorextechnology","cpe5":"edge\\+","cpe6":"lh320","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lorex_technology","cpe5":"edge2_lh330_firmware","cpe6":"11.17.38-33_1d97a","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lorex_technology","cpe5":"edge3_lh340_firmware","cpe6":"11.19.85_1fe3a","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lorex_technology","cpe5":"edge\\+_lh320_firmware","cpe6":"7-35-28-1b26e","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"1201","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lorex_technology","cpe5":"edge_lh310_firmware","cpe6":"7-35-28-1b26e","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2014","cve_id":"1201","cve":"CVE-2014-1201","epss":"0.231970000","percentile":"0.959650000","score_date":"2026-05-03","updated_at":"2026-05-04 00:13:06"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T09:34:40.455Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"20140110 [CVE -2014-1201] Lorex security DVR ActiveX control buffer overflow","tags":["mailing-list","x_refsource_BUGTRAQ","x_transferred"],"url":"http://www.securityfocus.com/archive/1/530739/100/0/threaded"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-testcase.html"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-report.txt"},{"name":"lorex-cve20141201-bo(90223)","tags":["vdb-entry","x_refsource_XF","x_transferred"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/90223"},{"name":"101903","tags":["vdb-entry","x_refsource_OSVDB","x_transferred"],"url":"http://osvdb.org/101903"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2014-01-09T00:00:00.000Z","descriptions":[{"lang":"en","value":"Buffer overflow in the INetViewX ActiveX control in the Lorex Edge LH310 and Edge+ LH320 series with firmware 7-35-28-1B26E, Edge2 LH330 series with firmware 11.17.38-33_1D97A, and Edge3 LH340 series with firmware 11.19.85_1FE3A allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long string in the HTTP_PORT parameter."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-10-09T18:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"20140110 [CVE -2014-1201] Lorex security DVR ActiveX control buffer overflow","tags":["mailing-list","x_refsource_BUGTRAQ"],"url":"http://www.securityfocus.com/archive/1/530739/100/0/threaded"},{"tags":["x_refsource_MISC"],"url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-testcase.html"},{"tags":["x_refsource_MISC"],"url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-report.txt"},{"name":"lorex-cve20141201-bo(90223)","tags":["vdb-entry","x_refsource_XF"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/90223"},{"name":"101903","tags":["vdb-entry","x_refsource_OSVDB"],"url":"http://osvdb.org/101903"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2014-1201","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Buffer overflow in the INetViewX ActiveX control in the Lorex Edge LH310 and Edge+ LH320 series with firmware 7-35-28-1B26E, Edge2 LH330 series with firmware 11.17.38-33_1D97A, and Edge3 LH340 series with firmware 11.19.85_1FE3A allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long string in the HTTP_PORT parameter."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"20140110 [CVE -2014-1201] Lorex security DVR ActiveX control buffer overflow","refsource":"BUGTRAQ","url":"http://www.securityfocus.com/archive/1/530739/100/0/threaded"},{"name":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-testcase.html","refsource":"MISC","url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-testcase.html"},{"name":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-report.txt","refsource":"MISC","url":"https://github.com/pedrib/PoC/blob/master/lorexActivex/lorex-report.txt"},{"name":"lorex-cve20141201-bo(90223)","refsource":"XF","url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/90223"},{"name":"101903","refsource":"OSVDB","url":"http://osvdb.org/101903"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2014-1201","datePublished":"2014-01-15T16:00:00.000Z","dateReserved":"2014-01-07T00:00:00.000Z","dateUpdated":"2024-08-06T09:34:40.455Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2014-01-15 16:08:18","lastModifiedDate":"2026-04-29 01:13:23","problem_types":["CWE-119","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lorex_technology:edge_lh310_firmware:7-35-28-1b26e:*:*:*:*:*:*:*","matchCriteriaId":"6AD26D4B-EC3A-4997-8D56-539B9399886F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:lorextechnology:edge:lh310:*:*:*:*:*:*:*","matchCriteriaId":"429A0C80-AED3-4CFE-A2C1-88A095B0BA29"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lorex_technology:edge3_lh340_firmware:11.19.85_1fe3a:*:*:*:*:*:*:*","matchCriteriaId":"3642678E-A727-49D0-92F6-290335ECD88D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:lorextechnology:edge3:lh340:*:*:*:*:*:*:*","matchCriteriaId":"786F19F5-9EB4-4AF1-B636-F4C47CA6A909"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lorex_technology:edge2_lh330_firmware:11.17.38-33_1d97a:*:*:*:*:*:*:*","matchCriteriaId":"DAF6F020-5EE1-4242-B513-41868162FD38"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:lorextechnology:edge2:lh330:*:*:*:*:*:*:*","matchCriteriaId":"8A062DB8-4AD6-44F8-AC4D-5FD940736C04"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lorex_technology:edge\\+_lh320_firmware:7-35-28-1b26e:*:*:*:*:*:*:*","matchCriteriaId":"3FFA0756-AB07-441B-9D5A-CCA338CD28DF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:lorextechnology:edge\\+:lh320:*:*:*:*:*:*:*","matchCriteriaId":"689A2308-F69F-45BF-86FB-0DA7CC391F2C"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2014","CveId":"1201","Ordinal":"1","Title":"CVE-2014-1201","CVE":"CVE-2014-1201","Year":"2014"},"notes":[{"CveYear":"2014","CveId":"1201","Ordinal":"1","NoteData":"Buffer overflow in the INetViewX ActiveX control in the Lorex Edge LH310 and Edge+ LH320 series with firmware 7-35-28-1B26E, Edge2 LH330 series with firmware 11.17.38-33_1D97A, and Edge3 LH340 series with firmware 11.19.85_1FE3A allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long string in the HTTP_PORT parameter.","Type":"Description","Title":"CVE-2014-1201"},{"CveYear":"2014","CveId":"1201","Ordinal":"2","NoteData":"2014-01-15","Type":"Other","Title":"Published"},{"CveYear":"2014","CveId":"1201","Ordinal":"3","NoteData":"2018-10-09","Type":"Other","Title":"Modified"}]}}}