{"api_version":"1","generated_at":"2026-07-23T08:48:09+00:00","cve":"CVE-2014-2343","urls":{"html":"https://cve.report/CVE-2014-2343","api":"https://cve.report/api/cve/CVE-2014-2343.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2014-2343","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2014-2343"},"summary":{"title":"Triangle MicroWorks SCADA Data Gateway Resource Exhaustion","description":"Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line.","state":"PUBLISHED","assigner":"icscert","published_at":"2014-05-30 23:55:02","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-400","CWE-20","CWE-400 CWE-400"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"2.1","severity":"","vector":"AV:L/AC:L/Au:N/C:N/I:N/A:P","data":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:N/I:N/A:P","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"}},{"version":"2.0","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"1.2","severity":"","vector":"AV:L/AC:H/Au:N/C:N/I:N/A:P","data":{"version":"2.0","vectorString":"AV:L/AC:H/Au:N/C:N/I:N/A:P","baseScore":1.2,"accessVector":"LOCAL","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"}},{"version":"2.0","source":"CNA","type":"CVSS","score":"1.2","severity":"","vector":"AV:L/AC:H/Au:N/C:N/I:N/A:P","data":{"accessComplexity":"HIGH","accessVector":"LOCAL","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":1.2,"confidentialityImpact":"NONE","integrityImpact":"NONE","vectorString":"AV:L/AC:H/Au:N/C:N/I:N/A:P","version":"2.0"}}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01","name":"http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["US Government Resource"],"title":"Triangle MicroWorks Uncontrolled Resource Consumption | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new","name":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"What's New","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2014-2343","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2014-2343","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Triangle MicroWorks","product":"SCADA Data Gateway","version":"affected v3.00.0635 custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Triangle MicroWorks has produced an update and release notes describing the mitigation. Please contact Triangle MicroWorks Support for details on specific platform updates here:\n\n http://www.trianglemicroworks.com/SupportPage.htm \n\nRelease notes are found here:\n\n http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new \n\nTriangle MicroWorks recommends following the International Electrotechnical Commission (IEC) Technical Specification TS 62351 to reduce the risk from vulnerability. More information on recommended implementation practices for Triangle MicroWorks products is available by contacting your product representative.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Adam Crain of Automatak and Chris Sistrunk of Mandiant","lang":"en"}],"nvd_cpes":[{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.50","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.50.0309","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.51","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.53","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0515","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0516","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0517","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0518","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0528","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0529","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0536","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0540","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0544","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0545","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0552","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0553","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0558","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0561","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0562","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0564","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0565","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0566","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0567","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0569","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0570","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0571","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0572","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0573","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0574","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0575","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0576","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0577","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0578","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0579","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0580","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0581","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0582","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0583","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0584","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0586","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0587","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0588","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0589","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0590","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0591","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0592","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0594","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0595","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0596","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0597","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0598","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"2.54.0599","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"3.00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"3.00.0612","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"3.00.0615","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"3.00.0616","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"3.00.0630","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"2343","vulnerable":"1","versionEndIncluding":"3.00.0633","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T10:14:25.054Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"}],"title":"CVE Program Container"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"SCADA Data Gateway","vendor":"Triangle MicroWorks","versions":[{"lessThan":"v3.00.0635","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Adam Crain of Automatak and Chris Sistrunk of Mandiant"}],"datePublic":"2014-05-29T06:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>\nTriangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line.\n\n</p>"}],"value":"Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line."}],"metrics":[{"cvssV2_0":{"accessComplexity":"HIGH","accessVector":"LOCAL","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":1.2,"confidentialityImpact":"NONE","integrityImpact":"NONE","vectorString":"AV:L/AC:H/Au:N/C:N/I:N/A:P","version":"2.0"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-400","description":"CWE-400","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-10-02T22:19:28.957Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Triangle MicroWorks has produced an update and release notes describing the mitigation. Please contact Triangle MicroWorks Support for details on specific platform updates here:</p><p><a target=\"_blank\" rel=\"nofollow\" href=\"http://www.trianglemicroworks.com/SupportPage.htm\">http://www.trianglemicroworks.com/SupportPage.htm</a></p><p>Release notes are found here:</p><p><a target=\"_blank\" rel=\"nofollow\" href=\"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new\">http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new</a></p><p>Triangle MicroWorks recommends following the International Electrotechnical Commission (IEC) Technical Specification TS 62351 to reduce the risk from vulnerability. More information on recommended implementation practices for Triangle MicroWorks products is available by contacting your product representative.</p>\n\n<br>"}],"value":"Triangle MicroWorks has produced an update and release notes describing the mitigation. Please contact Triangle MicroWorks Support for details on specific platform updates here:\n\n http://www.trianglemicroworks.com/SupportPage.htm \n\nRelease notes are found here:\n\n http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new \n\nTriangle MicroWorks recommends following the International Electrotechnical Commission (IEC) Technical Specification TS 62351 to reduce the risk from vulnerability. More information on recommended implementation practices for Triangle MicroWorks products is available by contacting your product representative."}],"source":{"advisory":"ICSA-14-149-01","discovery":"EXTERNAL"},"title":"Triangle MicroWorks SCADA Data Gateway Resource Exhaustion","x_generator":{"engine":"Vulnogram 0.2.0"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2014-2342","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new","refsource":"MISC","url":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"},{"name":"http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01","refsource":"MISC","url":"http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2014-2343","datePublished":"2014-05-30T23:00:00.000Z","dateReserved":"2014-03-13T00:00:00.000Z","dateUpdated":"2025-10-02T22:19:28.957Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2014-05-30 23:55:02","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-400","CWE-20","CWE-400 CWE-400"],"metrics":{"cvssMetricV2":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:H/Au:N/C:N/I:N/A:P","baseScore":1.2,"accessVector":"LOCAL","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"LOW","exploitabilityScore":1.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:N/I:N/A:P","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*","versionEndIncluding":"3.00.0633","matchCriteriaId":"A505671F-8C57-47A2-89D4-DC6186F5D7DA"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*","matchCriteriaId":"D2626C47-B68A-4A21-B5A2-9D64A28A7120"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*","matchCriteriaId":"69D2B52D-B324-4115-A3BB-51E3BF97758B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*","matchCriteriaId":"9406C4EC-5758-458D-8354-6736CA78A660"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*","matchCriteriaId":"EB915370-216E-40DC-AEF5-634230394E00"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*","matchCriteriaId":"22E5498C-D5F0-43F7-A536-AB65B4DEB49F"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*","matchCriteriaId":"2099DFC5-F241-4C47-9A17-FE40101A4570"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*","matchCriteriaId":"F1E898A9-7F0E-453C-8509-75E7E1290382"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*","matchCriteriaId":"E513983A-C6A2-4E07-874B-880F7A013D53"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*","matchCriteriaId":"D6861F70-5798-4B41-BE94-BECCF16752BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*","matchCriteriaId":"1B5722CA-130A-46B3-9A30-9661069890AF"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*","matchCriteriaId":"F5E625A4-30E4-4D5B-81B2-B0B0569948DB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*","matchCriteriaId":"5A6D03B5-2E8C-49E9-8A18-F367F72A4D50"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*","matchCriteriaId":"AF59F8E0-C4BA-4658-9B91-BACD59B9C482"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*","matchCriteriaId":"BD36BB8A-C840-494B-835C-98EB0075CA62"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*","matchCriteriaId":"8FDB5301-887B-4950-A918-113B75D2BDE5"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*","matchCriteriaId":"76BF9332-5F3E-4230-A742-2019B2DCEB22"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*","matchCriteriaId":"1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*","matchCriteriaId":"1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*","matchCriteriaId":"90EA0A71-B4C7-4F54-A439-4B0FA9637410"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*","matchCriteriaId":"71B02213-096E-4CA2-8528-64E83EA06D27"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*","matchCriteriaId":"8EA1B917-A27E-4043-BD74-534B13916F3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*","matchCriteriaId":"378C61EE-9420-42D3-9DA2-71F2D459ACE9"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*","matchCriteriaId":"CA21BE3B-6C2E-4479-A9A0-E3966741B832"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*","matchCriteriaId":"49C97936-8AF3-41D8-8D6B-F6C9C5F4B002"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*","matchCriteriaId":"D3175298-E0A4-4571-BDCC-FDA81675BC67"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*","matchCriteriaId":"18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*","matchCriteriaId":"E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*","matchCriteriaId":"00666362-AD62-4942-96E8-C08BF087E34F"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*","matchCriteriaId":"5BC82C89-7D15-452D-8610-23F3952487E9"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*","matchCriteriaId":"3D15DD91-4F01-4B95-8F9A-C4848800BDBB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*","matchCriteriaId":"9DF57506-CC34-473C-8165-CB26194E80BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*","matchCriteriaId":"CC480C77-1950-4C3A-B77E-D2C2AC59FE20"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*","matchCriteriaId":"2044B8C6-D0C6-4A1E-9798-19912FFAE097"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*","matchCriteriaId":"40D4B1C5-CE06-4082-9534-513BB99D7D7B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*","matchCriteriaId":"15E62697-E6BD-4796-9470-F6E125CD3F4C"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*","matchCriteriaId":"299D658E-143A-4556-A6FF-37EDA07828CF"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*","matchCriteriaId":"7619010A-954E-4F5D-8DDB-0ED652E2A306"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*","matchCriteriaId":"C042A0EB-AB96-4FD2-A19E-4E9101C2C63C"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*","matchCriteriaId":"B8B7B997-4D7F-4A34-822A-3AF52A4FA715"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*","matchCriteriaId":"3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*","matchCriteriaId":"2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*","matchCriteriaId":"0EC58901-067E-485B-9723-9F344F306C39"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*","matchCriteriaId":"E4583789-CC14-48BB-83B5-AF1B6896B10B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*","matchCriteriaId":"7CEC3409-0CED-41A8-8718-B0EFCA85DA49"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*","matchCriteriaId":"B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*","matchCriteriaId":"383DA8F4-1DDD-43A9-8A53-721F5F449CA2"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*","matchCriteriaId":"1AD95D30-4502-44EB-9C0C-D9A45CD24E5C"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*","matchCriteriaId":"B9F60297-9FA4-47F6-98AF-B9662568D76F"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*","matchCriteriaId":"4E593FD2-7158-40D0-9F44-01C06BF96F06"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*","matchCriteriaId":"0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*","matchCriteriaId":"5F210B77-F989-4931-AFBF-CEC2A175FC27"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*","matchCriteriaId":"36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*","matchCriteriaId":"F74C4546-500F-405C-B585-6F6C07065808"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0612:*:*:*:*:*:*:*","matchCriteriaId":"948521F4-CA30-4269-8A98-96F9AD004150"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0615:*:*:*:*:*:*:*","matchCriteriaId":"9D9853CB-38CC-419D-A9F8-EDDA2F6CE4F8"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*","matchCriteriaId":"7C679459-44C7-454C-9894-87ABE1F710F2"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0630:*:*:*:*:*:*:*","matchCriteriaId":"CD169173-9189-42BE-A741-955889E44FC9"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2014","CveId":"2343","Ordinal":"1","Title":"Triangle MicroWorks SCADA Data Gateway Resource Exhaustion","CVE":"CVE-2014-2343","Year":"2014"},"notes":[{"CveYear":"2014","CveId":"2343","Ordinal":"1","NoteData":"Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line.","Type":"Description","Title":"Triangle MicroWorks SCADA Data Gateway Resource Exhaustion"},{"CveYear":"2014","CveId":"2343","Ordinal":"2","NoteData":"2014-05-30","Type":"Other","Title":"Published"},{"CveYear":"2014","CveId":"2343","Ordinal":"3","NoteData":"2014-05-30","Type":"Other","Title":"Modified"}]}}}