{"api_version":"1","generated_at":"2026-07-23T06:37:45+00:00","cve":"CVE-2014-2358","urls":{"html":"https://cve.report/CVE-2014-2358","api":"https://cve.report/api/cve/CVE-2014-2358.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2014-2358","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2014-2358"},"summary":{"title":"Fox-IT DataDiode Appliance CSRF","description":"Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions.","state":"PUBLISHED","assigner":"icscert","published_at":"2014-10-19 01:55:10","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-352","CWE-352 CWE-352"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.8","severity":"","vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}},{"version":"2.0","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"4.3","severity":"","vector":"AV:N/AC:M/Au:N/C:N/I:N/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:N/A:P","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"}},{"version":"2.0","source":"CNA","type":"CVSS","score":"4.3","severity":"","vector":"AV:N/AC:M/Au:N/C:N/I:N/A:P","data":{"accessComplexity":"MEDIUM","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":4.3,"confidentialityImpact":"NONE","integrityImpact":"NONE","vectorString":"AV:N/AC:M/Au:N/C:N/I:N/A:P","version":"2.0"}}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-269-02","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-269-02","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Fox DataDiode Proxy Server CSRF Vulnerability | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2014-2358","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2014-2358","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Fox-IT","product":"DataDiode Appliance","version":"affected 1.7.1 custom","platforms":[]},{"source":"CNA","vendor":"Fox-IT","product":"DataDiode Appliance","version":"unaffected 1.7.2","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Fox-IT has released Version 1.7.2 of the Fox DataDiode Appliance that\n resolves the reported vulnerability. A Fox-IT product advisory titled \n“Fox DataDiode Appliance 1.7.2 advisory,” containing background and \npreparation information, as well as the upgrade instructions, are \navailable by contacting the local Fox-IT customer support.\n\n\nFox-IT also recommends the following actions:\n\n\n\n  *  All users of the Fox DataDiode Appliance should upgrade their systems to Version 1.7.2.\n\n  *  This installation consists of a reinstallation of the new version of\n the software. Therefore, the existing software configuration should be \nexported before this upgrade. This configuration can then be restored \nafter the upgrade.\n\n  *  Users are advised to change all passwords of administrator and user \naccounts in the Fox DataDiode Appliance, plus passwords used for FTP/SSL\n connections.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Tudor Enache of HelpAG","lang":"en"}],"nvd_cpes":[{"cve_year":"2014","cve_id":"2358","vulnerable":"1","versionEndIncluding":"1.7.1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"fox-it","cpe5":"fox_datadiode","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T10:14:25.516Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02"}],"title":"CVE Program Container"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"DataDiode Appliance","vendor":"Fox-IT","versions":[{"lessThanOrEqual":"1.7.1","status":"affected","version":"0","versionType":"custom"},{"status":"unaffected","version":"1.7.2"}]}],"credits":[{"lang":"en","type":"finder","value":"Tudor Enache of HelpAG"}],"datePublic":"2014-10-16T06:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions.</p>"}],"value":"Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions."}],"metrics":[{"cvssV2_0":{"accessComplexity":"MEDIUM","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":4.3,"confidentialityImpact":"NONE","integrityImpact":"NONE","vectorString":"AV:N/AC:M/Au:N/C:N/I:N/A:P","version":"2.0"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-352","description":"CWE-352","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-10-03T17:19:27.344Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-269-02"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Fox-IT has released Version 1.7.2 of the Fox DataDiode Appliance that\n resolves the reported vulnerability. A Fox-IT product advisory titled \n“Fox DataDiode Appliance 1.7.2 advisory,” containing background and \npreparation information, as well as the upgrade instructions, are \navailable by contacting the local Fox-IT customer support.</p>\n<p>Fox-IT also recommends the following actions:</p>\n<ul>\n<li>All users of the Fox DataDiode Appliance should upgrade their systems to Version 1.7.2.</li>\n<li>This installation consists of a reinstallation of the new version of\n the software. Therefore, the existing software configuration should be \nexported before this upgrade. This configuration can then be restored \nafter the upgrade.</li>\n<li>Users are advised to change all passwords of administrator and user \naccounts in the Fox DataDiode Appliance, plus passwords used for FTP/SSL\n connections.</li>\n</ul>\n\n<br>"}],"value":"Fox-IT has released Version 1.7.2 of the Fox DataDiode Appliance that\n resolves the reported vulnerability. A Fox-IT product advisory titled \n“Fox DataDiode Appliance 1.7.2 advisory,” containing background and \npreparation information, as well as the upgrade instructions, are \navailable by contacting the local Fox-IT customer support.\n\n\nFox-IT also recommends the following actions:\n\n\n\n  *  All users of the Fox DataDiode Appliance should upgrade their systems to Version 1.7.2.\n\n  *  This installation consists of a reinstallation of the new version of\n the software. Therefore, the existing software configuration should be \nexported before this upgrade. This configuration can then be restored \nafter the upgrade.\n\n  *  Users are advised to change all passwords of administrator and user \naccounts in the Fox DataDiode Appliance, plus passwords used for FTP/SSL\n connections."}],"source":{"advisory":"ICSA-14-269-02","discovery":"EXTERNAL"},"title":"Fox-IT DataDiode Appliance CSRF","x_generator":{"engine":"Vulnogram 0.2.0"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2014-2358","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2014-2358","datePublished":"2014-10-19T01:00:00.000Z","dateReserved":"2014-03-13T00:00:00.000Z","dateUpdated":"2025-10-03T17:19:27.344Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2014-10-19 01:55:10","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-352","CWE-352 CWE-352"],"metrics":{"cvssMetricV2":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:N/A:P","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:fox-it:fox_datadiode:*:*:*:*:*:*:*:*","versionEndIncluding":"1.7.1","matchCriteriaId":"312C1C72-F161-4547-BF38-51402F48E5A4"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2014","CveId":"2358","Ordinal":"1","Title":"Fox-IT DataDiode Appliance CSRF","CVE":"CVE-2014-2358","Year":"2014"},"notes":[{"CveYear":"2014","CveId":"2358","Ordinal":"1","NoteData":"Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions.","Type":"Description","Title":"Fox-IT DataDiode Appliance CSRF"},{"CveYear":"2014","CveId":"2358","Ordinal":"2","NoteData":"2014-10-18","Type":"Other","Title":"Published"},{"CveYear":"2014","CveId":"2358","Ordinal":"3","NoteData":"2014-10-18","Type":"Other","Title":"Modified"}]}}}