{"api_version":"1","generated_at":"2026-07-23T08:31:03+00:00","cve":"CVE-2014-5430","urls":{"html":"https://cve.report/CVE-2014-5430","api":"https://cve.report/api/cve/CVE-2014-5430.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2014-5430","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2014-5430"},"summary":{"title":"CVE-2014-5430","description":"Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program.","state":"PUBLISHED","assigner":"icscert","published_at":"2014-11-07 11:55:03","updated_at":"2026-05-06 22:30:45"},"problem_types":["NVD-CWE-Other","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.9","severity":"","vector":"AV:L/AC:M/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:C/I:C/A:C","baseScore":6.9,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-308-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-14-308-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["US Government Resource"],"title":"ABB RobotStudio and Test Signal Viewer DLL Hijack Vulnerability | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2014-5430","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2014-5430","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2014","cve_id":"5430","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"abb","cpe5":"robotstudio","cpe6":"5.60","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"5430","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"abb","cpe5":"robotstudio","cpe6":"5.61","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"5430","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"abb","cpe5":"robotstudio","cpe6":"5.61.01","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"5430","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"abb","cpe5":"test_signal_viewer","cpe6":"1.5","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T11:41:49.251Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-308-01"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2014-11-04T00:00:00.000Z","descriptions":[{"lang":"en","value":"Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2014-11-07T08:57:00.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-308-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2014-5430","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-14-308-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-308-01"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2014-5430","datePublished":"2014-11-07T11:00:00.000Z","dateReserved":"2014-08-22T00:00:00.000Z","dateUpdated":"2024-08-06T11:41:49.251Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2014-11-07 11:55:03","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["NVD-CWE-Other","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:C/I:C/A:C","baseScore":6.9,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"MEDIUM","exploitabilityScore":3.4,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:abb:robotstudio:5.60:*:*:*:*:*:*:*","matchCriteriaId":"58E1E1D8-8A19-49D1-9193-A50B51A62D7B"},{"vulnerable":true,"criteria":"cpe:2.3:a:abb:robotstudio:5.61:*:*:*:*:*:*:*","matchCriteriaId":"5DD3D4F9-EC5C-4603-AEC7-02DF279D7B91"},{"vulnerable":true,"criteria":"cpe:2.3:a:abb:robotstudio:5.61.01:*:*:*:*:*:*:*","matchCriteriaId":"D2F3F706-BC63-4C7E-82CC-8196BAF4F0DF"},{"vulnerable":true,"criteria":"cpe:2.3:a:abb:test_signal_viewer:1.5:*:*:*:*:*:*:*","matchCriteriaId":"BAEB0B80-6423-4FD4-8B2A-6332A6EFE752"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2014","CveId":"5430","Ordinal":"1","Title":"CVE-2014-5430","CVE":"CVE-2014-5430","Year":"2014"},"notes":[{"CveYear":"2014","CveId":"5430","Ordinal":"1","NoteData":"Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program.","Type":"Description","Title":"CVE-2014-5430"},{"CveYear":"2014","CveId":"5430","Ordinal":"2","NoteData":"2014-11-07","Type":"Other","Title":"Published"},{"CveYear":"2014","CveId":"5430","Ordinal":"3","NoteData":"2014-11-07","Type":"Other","Title":"Modified"}]}}}