{"api_version":"1","generated_at":"2026-07-23T18:57:19+00:00","cve":"CVE-2014-7249","urls":{"html":"https://cve.report/CVE-2014-7249","api":"https://cve.report/api/cve/CVE-2014-7249.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2014-7249","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2014-7249"},"summary":{"title":"CVE-2014-7249","description":"Buffer overflow on the Allied Telesis AR440S, AR441S, AR442S, AR745, AR750S, AR750S-DP, AT-8624POE, AT-8624T/2M, AT-8648T/2SP, AT-8748XL, AT-8848, AT-9816GB, AT-9924T, AT-9924Ts, CentreCOM AR415S, CentreCOM AR450S, CentreCOM AR550S, CentreCOM AR570S, CentreCOM 8700SL, CentreCOM 8948XL, CentreCOM 9924SP, CentreCOM 9924T/4SP, Rapier 48i, and SwitchBlade4000 with firmware before 2.9.1-21 allows remote attackers to execute arbitrary code via a crafted HTTP POST request.","state":"PUBLISHED","assigner":"jpcert","published_at":"2014-12-19 11:59:01","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-119","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://jvndb.jvn.jp/jvndb/JVNDB-2014-000132","name":"http://jvndb.jvn.jp/jvndb/JVNDB-2014-000132","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://jvn.jp/en/jp/JVN22440986/index.html","name":"http://jvn.jp/en/jp/JVN22440986/index.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"JVN#22440986: Multiple Allied Telesis products vulnerable to buffer overflow","mime":"text/xml","httpstatus":"200","archivestatus":"200"},{"url":"http://www.allied-telesis.co.jp/support/list/faq/vuls/20141111aen.html","name":"http://www.allied-telesis.co.jp/support/list/faq/vuls/20141111aen.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2014-7249","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2014-7249","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"ar440s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"ar440s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"ar441s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"ar441s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"ar442s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"ar442s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"ar745","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"ar745_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"ar750s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"ar750s-dp","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"ar750s-dp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"ar750s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-8624poe","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-8624poe_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-8624t\\/2m","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-8624t\\/2m_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-8648t\\/2sp","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-8648t\\/2sp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-8748xl","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-8748xl_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-8848","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-8848_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-9816gb","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-9816gb_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-9924t","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"at-9924ts","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-9924ts_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"at-9924t_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_8700sl_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_8948xl","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_8948xl_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_9924sp","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_9924sp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_9924t\\/4sp","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_9924t\\/4sp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_ar415s","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_ar415s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_ar450s","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_ar450s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_ar550s","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_ar550s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_ar570s","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"centrecom_ar570s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"centrecom_ar8700sl","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"rapier_48i","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"rapier_48i_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alliedtelesis","cpe5":"switchblade4000","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2014","cve_id":"7249","vulnerable":"1","versionEndIncluding":"2.9.1-20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alliedtelesis","cpe5":"switchblade4000_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T12:40:19.261Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"JVN#22440986","tags":["third-party-advisory","x_refsource_JVN","x_transferred"],"url":"http://jvn.jp/en/jp/JVN22440986/index.html"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://www.allied-telesis.co.jp/support/list/faq/vuls/20141111aen.html"},{"name":"JVNDB-2014-000132","tags":["third-party-advisory","x_refsource_JVNDB","x_transferred"],"url":"http://jvndb.jvn.jp/jvndb/JVNDB-2014-000132"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2014-11-11T00:00:00.000Z","descriptions":[{"lang":"en","value":"Buffer overflow on the Allied Telesis AR440S, AR441S, AR442S, AR745, AR750S, AR750S-DP, AT-8624POE, AT-8624T/2M, AT-8648T/2SP, AT-8748XL, AT-8848, AT-9816GB, AT-9924T, AT-9924Ts, CentreCOM AR415S, CentreCOM AR450S, CentreCOM AR550S, CentreCOM AR570S, CentreCOM 8700SL, CentreCOM 8948XL, CentreCOM 9924SP, CentreCOM 9924T/4SP, Rapier 48i, and SwitchBlade4000 with firmware before 2.9.1-21 allows remote attackers to execute arbitrary code via a crafted HTTP POST request."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2014-12-19T09:57:00.000Z","orgId":"ede6fdc4-6654-4307-a26d-3331c018e2ce","shortName":"jpcert"},"references":[{"name":"JVN#22440986","tags":["third-party-advisory","x_refsource_JVN"],"url":"http://jvn.jp/en/jp/JVN22440986/index.html"},{"tags":["x_refsource_CONFIRM"],"url":"http://www.allied-telesis.co.jp/support/list/faq/vuls/20141111aen.html"},{"name":"JVNDB-2014-000132","tags":["third-party-advisory","x_refsource_JVNDB"],"url":"http://jvndb.jvn.jp/jvndb/JVNDB-2014-000132"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"vultures@jpcert.or.jp","ID":"CVE-2014-7249","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Buffer overflow on the Allied Telesis AR440S, AR441S, AR442S, AR745, AR750S, AR750S-DP, AT-8624POE, AT-8624T/2M, AT-8648T/2SP, AT-8748XL, AT-8848, AT-9816GB, AT-9924T, AT-9924Ts, CentreCOM AR415S, CentreCOM AR450S, CentreCOM AR550S, CentreCOM AR570S, CentreCOM 8700SL, CentreCOM 8948XL, CentreCOM 9924SP, CentreCOM 9924T/4SP, Rapier 48i, and SwitchBlade4000 with firmware before 2.9.1-21 allows remote attackers to execute arbitrary code via a crafted HTTP POST request."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"JVN#22440986","refsource":"JVN","url":"http://jvn.jp/en/jp/JVN22440986/index.html"},{"name":"http://www.allied-telesis.co.jp/support/list/faq/vuls/20141111aen.html","refsource":"CONFIRM","url":"http://www.allied-telesis.co.jp/support/list/faq/vuls/20141111aen.html"},{"name":"JVNDB-2014-000132","refsource":"JVNDB","url":"http://jvndb.jvn.jp/jvndb/JVNDB-2014-000132"}]}}}},"cveMetadata":{"assignerOrgId":"ede6fdc4-6654-4307-a26d-3331c018e2ce","assignerShortName":"jpcert","cveId":"CVE-2014-7249","datePublished":"2014-12-19T11:00:00.000Z","dateReserved":"2014-09-30T00:00:00.000Z","dateUpdated":"2024-08-06T12:40:19.261Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2014-12-19 11:59:01","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-119","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_ar415s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"6790CB5F-F5E2-4276-B3CA-7FA46878B569"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_ar415s:*:*:*:*:*:*:*:*","matchCriteriaId":"5C77F0C7-CE53-46E5-BB5D-5F947A6A8429"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-8624t\\/2m_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"CFD12D46-E5A2-46A3-BE9F-931E7DB4C210"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-8624t\\/2m:*:*:*:*:*:*:*:*","matchCriteriaId":"ECBDA7EA-09D6-4874-A9D1-0181AF97CC7F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:ar442s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"4C7ACB87-0EAB-4A41-AA41-5913A99E213C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:ar442s:-:*:*:*:*:*:*:*","matchCriteriaId":"12592CF4-C917-4270-9E58-8B530507327F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-9924t_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"B11EA4A9-C569-4F50-8962-D0ECF6E3155F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-9924t:*:*:*:*:*:*:*:*","matchCriteriaId":"EB289C3A-B506-41DE-98B3-EF1A221A282A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-8848_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"4E2663DA-B4E3-411E-85B1-B52579F29648"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-8848:*:*:*:*:*:*:*:*","matchCriteriaId":"EFDC6607-91AD-46AC-810D-C7A7F214CEDA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:rapier_48i_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"099A272B-6803-49D5-91C9-D407FA768FC9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:rapier_48i:*:*:*:*:*:*:*:*","matchCriteriaId":"7DB3C344-E2F8-4B44-8DB3-9CDC440A7A3A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_ar450s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"E913B84C-76AE-4977-8AA1-B4DF719D8D95"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_ar450s:*:*:*:*:*:*:*:*","matchCriteriaId":"EC7212C5-F3DA-4FD0-B5F0-A17B33890AFB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:ar745_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"160495A1-0720-4AF6-88A1-FC35C5590A90"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:ar745:-:*:*:*:*:*:*:*","matchCriteriaId":"01A5F497-AD41-4B17-9512-E51C67BE5FA9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:ar441s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"8E41E7B4-3938-4462-814B-C0D2651300A9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:ar441s:-:*:*:*:*:*:*:*","matchCriteriaId":"CA421FDA-4ED3-4EA9-882C-D324378E2B4C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_9924sp_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"28FF1C34-4434-46AA-848B-99CA26AEEB9E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_9924sp:*:*:*:*:*:*:*:*","matchCriteriaId":"891B0B06-B1A7-4C74-8C36-9765167F0B5B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:switchblade4000_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"845E30B2-E656-4A41-AB3A-08A626AF9C79"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:switchblade4000:*:*:*:*:*:*:*:*","matchCriteriaId":"EE5C3C0B-FCD2-4554-842C-9FFFC90FF27D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-8624poe_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"F9408776-E700-4C0B-90C4-B1D9196E51E6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-8624poe:*:*:*:*:*:*:*:*","matchCriteriaId":"45866236-EA04-4874-81FA-C8DC0563A1B6"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_9924t\\/4sp_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"8CB728D8-0DB3-4ED7-905C-C6A99DB7B59D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_9924t\\/4sp:*:*:*:*:*:*:*:*","matchCriteriaId":"1F6BDF0D-9BB7-47DA-991A-C87CC60C80B9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-9816gb_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"445007A4-FAAF-4CB0-B80F-57FE389E5C30"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-9816gb:*:*:*:*:*:*:*:*","matchCriteriaId":"EC17B2B0-1795-4528-B997-DEAEF3BCCF0E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-9924ts_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"97AE756A-FDC5-4F78-B5A2-1F0BA76336F4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-9924ts:*:*:*:*:*:*:*:*","matchCriteriaId":"2BB7E5CD-B66F-434B-83C1-F31ADB903186"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:ar750s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"B1EB5160-2D62-4AC6-8F36-429936A18546"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:ar750s:-:*:*:*:*:*:*:*","matchCriteriaId":"435E4169-F025-4194-ACA2-FE2CCF6F2F4E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_ar570s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"80AA0879-B180-4A28-A059-9C6F9E50A58F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_ar570s:*:*:*:*:*:*:*:*","matchCriteriaId":"01ECC037-75DD-452D-AAD1-5678E8D11845"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_8948xl_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"611FF70C-9A67-48F3-8D52-C70FBA02D83F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_8948xl:*:*:*:*:*:*:*:*","matchCriteriaId":"5E02ED13-C13C-4F06-A4BF-85C72A6B0F15"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-8648t\\/2sp_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"965C6820-A8F7-4FBF-B2CF-BB075B1DF596"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-8648t\\/2sp:*:*:*:*:*:*:*:*","matchCriteriaId":"14124400-8FEF-4142-817A-540B2EB15BD5"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_8700sl_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"424A4E44-B707-40E5-9343-30255693E218"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_ar8700sl:*:*:*:*:*:*:*:*","matchCriteriaId":"878A6AA2-4BEF-4BAC-9799-CE202DB47FBC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:ar750s-dp_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"CDAC60F8-2E66-4F59-B29C-106C9239AB46"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:ar750s-dp:-:*:*:*:*:*:*:*","matchCriteriaId":"1F34FFA3-4CBA-4C3A-ABD0-DE3AB90FF70F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:centrecom_ar550s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"1AC86538-F3FE-4139-8A69-AABBE25B7EAC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:centrecom_ar550s:*:*:*:*:*:*:*:*","matchCriteriaId":"7353EADC-20ED-4F5C-ACC2-4201FFAF8CBB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:at-8748xl_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"D55C6251-2F67-47AA-AD07-7ADF6BE65817"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:at-8748xl:*:*:*:*:*:*:*:*","matchCriteriaId":"80E859F2-79EC-4D79-B57D-252D2BE9CB4F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alliedtelesis:ar440s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.9.1-20","matchCriteriaId":"1FBE91F0-47A0-4FE7-BFBD-55839DFC38EB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:alliedtelesis:ar440s:-:*:*:*:*:*:*:*","matchCriteriaId":"5619B8C4-40F4-44AF-BA6C-1E85A1272881"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2014","CveId":"7249","Ordinal":"1","Title":"CVE-2014-7249","CVE":"CVE-2014-7249","Year":"2014"},"notes":[{"CveYear":"2014","CveId":"7249","Ordinal":"1","NoteData":"Buffer overflow on the Allied Telesis AR440S, AR441S, AR442S, AR745, AR750S, AR750S-DP, AT-8624POE, AT-8624T/2M, AT-8648T/2SP, AT-8748XL, AT-8848, AT-9816GB, AT-9924T, AT-9924Ts, CentreCOM AR415S, CentreCOM AR450S, CentreCOM AR550S, CentreCOM AR570S, CentreCOM 8700SL, CentreCOM 8948XL, CentreCOM 9924SP, CentreCOM 9924T/4SP, Rapier 48i, and SwitchBlade4000 with firmware before 2.9.1-21 allows remote attackers to execute arbitrary code via a crafted HTTP POST request.","Type":"Description","Title":"CVE-2014-7249"},{"CveYear":"2014","CveId":"7249","Ordinal":"2","NoteData":"2014-12-19","Type":"Other","Title":"Published"},{"CveYear":"2014","CveId":"7249","Ordinal":"3","NoteData":"2014-12-19","Type":"Other","Title":"Modified"}]}}}