{"api_version":"1","generated_at":"2026-07-23T05:09:38+00:00","cve":"CVE-2015-1012","urls":{"html":"https://cve.report/CVE-2015-1012","api":"https://cve.report/api/cve/CVE-2015-1012.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2015-1012","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2015-1012"},"summary":{"title":"CVE-2015-1012","description":"Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2019-03-25 19:29:00","updated_at":"2019-10-09 23:13:00"},"problem_types":["CWE-200"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01","refsource":"MISC","tags":["Mitigation","Third Party Advisory","US Government Resource"],"title":"Hospira LifeCare PCA Infusion System Vulnerabilities (Update B) | ICS-CERT","mime":"text/html","httpstatus":"403","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2015-1012","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2015-1012","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2015","cve_id":"1012","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"pfizer","cpe5":"lifecare_pca_infusion_system","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2015","cve_id":"1012","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"pfizer","cpe5":"lifecare_pca_infusion_system","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2015","cve_id":"1012","vulnerable":"1","versionEndIncluding":"5.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"pfizer","cpe5":"lifecare_pca_infusion_system_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2015-1012","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Hospira","product":{"product_data":[{"product_name":"LifeCare PCA Infusion System","version":{"version_data":[{"version_value":"<= 5.0"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Cleartext storage of sensitive information CWE-312"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01","url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01"}]},"description":{"description_data":[{"lang":"eng","value":"Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access."}]}},"nvd":{"publishedDate":"2019-03-25 19:29:00","lastModifiedDate":"2019-10-09 23:13:00","problem_types":["CWE-200"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:pfizer:lifecare_pca_infusion_system_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"5.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:pfizer:lifecare_pca_infusion_system:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2015","CveId":"1012","Ordinal":"77707","Title":"CVE-2015-1012","CVE":"CVE-2015-1012","Year":"2015"},"notes":[{"CveYear":"2015","CveId":"1012","Ordinal":"1","NoteData":"Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access.","Type":"Description","Title":null},{"CveYear":"2015","CveId":"1012","Ordinal":"2","NoteData":"2019-03-25","Type":"Other","Title":"Published"},{"CveYear":"2015","CveId":"1012","Ordinal":"3","NoteData":"2019-03-25","Type":"Other","Title":"Modified"}]}}}