{"api_version":"1","generated_at":"2026-07-23T05:58:06+00:00","cve":"CVE-2015-7907","urls":{"html":"https://cve.report/CVE-2015-7907","api":"https://cve.report/api/cve/CVE-2015-7907.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2015-7907","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2015-7907"},"summary":{"title":"CVE-2015-7907","description":"Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors.","state":"PUBLISHED","assigner":"icscert","published_at":"2015-12-21 11:59:09","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-22","n/a"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"8.6","severity":"HIGH","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"LOW"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.4","severity":"","vector":"AV:N/AC:L/Au:N/C:N/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:P","baseScore":6.4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Honeywell Midas Gas Detector Vulnerabilities | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2015-7907","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2015-7907","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2015","cve_id":"7907","vulnerable":"1","versionEndIncluding":"2.13b1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"honeywell","cpe5":"midas_black_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2015","cve_id":"7907","vulnerable":"1","versionEndIncluding":"1.13b1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"honeywell","cpe5":"midas_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T08:06:31.053Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2015-12-03T00:00:00.000Z","descriptions":[{"lang":"en","value":"Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2015-12-21T08:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2015-7907","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2015-7907","datePublished":"2015-12-21T11:00:00.000Z","dateReserved":"2015-10-22T00:00:00.000Z","dateUpdated":"2024-08-06T08:06:31.053Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2015-12-21 11:59:09","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-22","n/a"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"LOW"},"exploitabilityScore":3.9,"impactScore":4.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:P","baseScore":6.4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10,"impactScore":4.9,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:honeywell:midas_black_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.13b1","matchCriteriaId":"71AF6C8E-7ABC-4885-8199-FBC20184143B"},{"vulnerable":true,"criteria":"cpe:2.3:o:honeywell:midas_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.13b1","matchCriteriaId":"56D32C02-3E80-42C7-97A9-C308BDCC2EAC"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2015","CveId":"7907","Ordinal":"1","Title":"CVE-2015-7907","CVE":"CVE-2015-7907","Year":"2015"},"notes":[{"CveYear":"2015","CveId":"7907","Ordinal":"1","NoteData":"Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors.","Type":"Description","Title":"CVE-2015-7907"},{"CveYear":"2015","CveId":"7907","Ordinal":"2","NoteData":"2015-12-21","Type":"Other","Title":"Published"},{"CveYear":"2015","CveId":"7907","Ordinal":"3","NoteData":"2015-12-21","Type":"Other","Title":"Modified"}]}}}