{"api_version":"1","generated_at":"2026-07-23T06:58:06+00:00","cve":"CVE-2015-8561","urls":{"html":"https://cve.report/CVE-2015-8561","api":"https://cve.report/api/cve/CVE-2015-8561.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2015-8561","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2015-8561"},"summary":{"title":"CVE-2015-8561","description":"The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.","state":"PUBLISHED","assigner":"mitre","published_at":"2015-12-15 05:59:09","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-119","n/a"],"metrics":[{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.8","severity":"","vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Schneider Electric ProClima ActiveX Control Vulnerabilities | ICS-CERT","mime":"application/octet-stream","httpstatus":"200","archivestatus":"200"},{"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-628","name":"http://www.zerodayinitiative.com/advisories/ZDI-15-628","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ZDI-15-628 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-627","name":"http://www.zerodayinitiative.com/advisories/ZDI-15-627","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ZDI-15-627 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-629","name":"http://www.zerodayinitiative.com/advisories/ZDI-15-629","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ZDI-15-629 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-626","name":"http://www.zerodayinitiative.com/advisories/ZDI-15-626","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"ZDI-15-626 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01","name":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"401"},{"url":"https://www.cve.org/CVERecord?id=CVE-2015-8561","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2015-8561","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2015","cve_id":"8561","vulnerable":"1","versionEndIncluding":"6.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"proclima","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T08:20:43.541Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-628"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-626"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-627"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-629"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2015-12-15T02:00:00.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-628"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-626"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-627"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-629"},{"tags":["x_refsource_CONFIRM"],"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2015-8561","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-628","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-628"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-626","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-626"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-627","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-627"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-629","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-629"},{"name":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01","refsource":"CONFIRM","url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2015-8561","datePublished":"2015-12-15T02:00:00.000Z","dateReserved":"2015-12-14T00:00:00.000Z","dateUpdated":"2024-09-17T02:33:11.923Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2015-12-15 05:59:09","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-119","n/a"],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*","versionEndIncluding":"6.1","matchCriteriaId":"12DFD1A6-BDB8-4864-A3E3-1CBF1609C17B"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2015","CveId":"8561","Ordinal":"1","Title":"CVE-2015-8561","CVE":"CVE-2015-8561","Year":"2015"},"notes":[{"CveYear":"2015","CveId":"8561","Ordinal":"1","NoteData":"The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.","Type":"Description","Title":"CVE-2015-8561"},{"CveYear":"2015","CveId":"8561","Ordinal":"2","NoteData":"2015-12-14","Type":"Other","Title":"Published"}]}}}