{"api_version":"1","generated_at":"2026-07-23T19:43:55+00:00","cve":"CVE-2016-0861","urls":{"html":"https://cve.report/CVE-2016-0861","api":"https://cve.report/api/cve/CVE-2016-0861.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2016-0861","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2016-0861"},"summary":{"title":"CVE-2016-0861","description":"General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors.","state":"PUBLISHED","assigner":"icscert","published_at":"2016-02-05 11:59:00","updated_at":"2026-05-06 22:30:45"},"problem_types":["CWE-77","n/a"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"8.8","severity":"HIGH","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"9","severity":"","vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"https://www.exploit-db.com/exploits/39408/","name":"https://www.exploit-db.com/exploits/39408/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"GE Industrial Solutions UPS SNMP Adapter < 4.8 - Multiple Vulnerabilities - Hardware webapps Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://apps.geindustrial.com/publibrary/checkout/Application%20and%20Technical%7CGEIS_SNMP%7CPDF&filename=GEIS_SNMP.pdf","name":"http://apps.geindustrial.com/publibrary/checkout/Application%20and%20Technical%7CGEIS_SNMP%7CPDF&filename=GEIS_SNMP.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"","mime":"text/html","httpstatus":"503","archivestatus":"503"},{"url":"http://packetstormsecurity.com/files/135586/GE-Industrial-Solutions-UPS-SNMP-Adapter-Command-Injection.html","name":"http://packetstormsecurity.com/files/135586/GE-Industrial-Solutions-UPS-SNMP-Adapter-Command-Injection.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"GE Industrial Solutions UPS SNMP Adapter Command Injection ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-033-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-16-033-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"GE SNMP/Web Interface Vulnerabilities | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://seclists.org/fulldisclosure/2016/Feb/21","name":"http://seclists.org/fulldisclosure/2016/Feb/21","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Full Disclosure: GE Industrial Solutions - UPS SNMP Adapter Command Injection and Clear-text Sensitive Info Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2016-0861","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2016-0861","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2016","cve_id":"861","vulnerable":"1","versionEndIncluding":"4.7","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ge","cpe5":"ups_snmp_web_adapter_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T22:30:05.162Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://apps.geindustrial.com/publibrary/checkout/Application%20and%20Technical%7CGEIS_SNMP%7CPDF&filename=GEIS_SNMP.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://packetstormsecurity.com/files/135586/GE-Industrial-Solutions-UPS-SNMP-Adapter-Command-Injection.html"},{"name":"20160203 GE Industrial Solutions - UPS SNMP Adapter Command Injection and Clear-text Sensitive Info Vulnerabilities","tags":["mailing-list","x_refsource_FULLDISC","x_transferred"],"url":"http://seclists.org/fulldisclosure/2016/Feb/21"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-033-02"},{"name":"39408","tags":["exploit","x_refsource_EXPLOIT-DB","x_transferred"],"url":"https://www.exploit-db.com/exploits/39408/"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2016-01-27T00:00:00.000Z","descriptions":[{"lang":"en","value":"General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-09-09T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"http://apps.geindustrial.com/publibrary/checkout/Application%20and%20Technical%7CGEIS_SNMP%7CPDF&filename=GEIS_SNMP.pdf"},{"tags":["x_refsource_MISC"],"url":"http://packetstormsecurity.com/files/135586/GE-Industrial-Solutions-UPS-SNMP-Adapter-Command-Injection.html"},{"name":"20160203 GE Industrial Solutions - UPS SNMP Adapter Command Injection and Clear-text Sensitive Info Vulnerabilities","tags":["mailing-list","x_refsource_FULLDISC"],"url":"http://seclists.org/fulldisclosure/2016/Feb/21"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-033-02"},{"name":"39408","tags":["exploit","x_refsource_EXPLOIT-DB"],"url":"https://www.exploit-db.com/exploits/39408/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2016-0861","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://apps.geindustrial.com/publibrary/checkout/Application%20and%20Technical%7CGEIS_SNMP%7CPDF&filename=GEIS_SNMP.pdf","refsource":"CONFIRM","url":"http://apps.geindustrial.com/publibrary/checkout/Application%20and%20Technical%7CGEIS_SNMP%7CPDF&filename=GEIS_SNMP.pdf"},{"name":"http://packetstormsecurity.com/files/135586/GE-Industrial-Solutions-UPS-SNMP-Adapter-Command-Injection.html","refsource":"MISC","url":"http://packetstormsecurity.com/files/135586/GE-Industrial-Solutions-UPS-SNMP-Adapter-Command-Injection.html"},{"name":"20160203 GE Industrial Solutions - UPS SNMP Adapter Command Injection and Clear-text Sensitive Info Vulnerabilities","refsource":"FULLDISC","url":"http://seclists.org/fulldisclosure/2016/Feb/21"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-16-033-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-033-02"},{"name":"39408","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/39408/"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2016-0861","datePublished":"2016-02-05T11:00:00.000Z","dateReserved":"2015-12-17T00:00:00.000Z","dateUpdated":"2024-08-05T22:30:05.162Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2016-02-05 11:59:00","lastModifiedDate":"2026-05-06 22:30:45","problem_types":["CWE-77","n/a"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8,"impactScore":10,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:ge:ups_snmp_web_adapter_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"4.7","matchCriteriaId":"B4F36139-3AB5-42B0-8950-274924E48F16"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2016","CveId":"861","Ordinal":"1","Title":"CVE-2016-0861","CVE":"CVE-2016-0861","Year":"2016"},"notes":[{"CveYear":"2016","CveId":"861","Ordinal":"1","NoteData":"General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors.","Type":"Description","Title":"CVE-2016-0861"},{"CveYear":"2016","CveId":"861","Ordinal":"2","NoteData":"2016-02-05","Type":"Other","Title":"Published"},{"CveYear":"2016","CveId":"861","Ordinal":"3","NoteData":"2017-09-09","Type":"Other","Title":"Modified"}]}}}