{"api_version":"1","generated_at":"2026-07-23T04:26:48+00:00","cve":"CVE-2016-5809","urls":{"html":"https://cve.report/CVE-2016-5809","api":"https://cve.report/api/cve/CVE-2016-5809.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2016-5809","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2016-5809"},"summary":{"title":"CVE-2016-5809","description":"An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.","state":"PUBLISHED","assigner":"icscert","published_at":"2017-02-13 21:59:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-352","Schneider Electric IONXXXX Series csrf"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"8.8","severity":"HIGH","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6.8","severity":"","vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03","name":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Schneider Electric IONXXXX Series Power Meter Vulnerabilities | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/92916","name":"http://www.securityfocus.com/bid/92916","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Schneider Electric ION Power Meter Unspecified Cross Site Request Forgery Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.exploit-db.com/exploits/44640/","name":"https://www.exploit-db.com/exploits/44640/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Powerlogic/Schneider Electric IONXXXX Series - Cross-Site Request Forgery - Linux webapps Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2016-5809","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2016-5809","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Schneider Electric IONXXXX Series","version":"affected Schneider Electric IONXXXX Series","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2016","cve_id":"5809","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"ion5000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"5809","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"ion7300","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"5809","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"ion7500","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"5809","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"ion7600","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"5809","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"ion8650","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"5809","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"ion8800","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T01:15:10.763Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"44640","tags":["exploit","x_refsource_EXPLOIT-DB","x_transferred"],"url":"https://www.exploit-db.com/exploits/44640/"},{"name":"92916","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/92916"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"Schneider Electric IONXXXX Series","vendor":"n/a","versions":[{"status":"affected","version":"Schneider Electric IONXXXX Series"}]}],"datePublic":"2017-02-13T00:00:00.000Z","descriptions":[{"lang":"en","value":"An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved."}],"problemTypes":[{"descriptions":[{"description":"Schneider Electric IONXXXX Series csrf","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-05-19T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"name":"44640","tags":["exploit","x_refsource_EXPLOIT-DB"],"url":"https://www.exploit-db.com/exploits/44640/"},{"name":"92916","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/92916"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2016-5809","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric IONXXXX Series","version":{"version_data":[{"version_value":"Schneider Electric IONXXXX Series"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Schneider Electric IONXXXX Series csrf"}]}]},"references":{"reference_data":[{"name":"44640","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/44640/"},{"name":"92916","refsource":"BID","url":"http://www.securityfocus.com/bid/92916"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2016-5809","datePublished":"2017-02-13T21:00:00.000Z","dateReserved":"2016-06-23T00:00:00.000Z","dateUpdated":"2024-08-06T01:15:10.763Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-02-13 21:59:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-352","Schneider Electric IONXXXX Series csrf"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:ion5000:-:*:*:*:*:*:*:*","matchCriteriaId":"B0DA1F9F-A898-4059-93FB-05F5C28280E1"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:ion7300:-:*:*:*:*:*:*:*","matchCriteriaId":"5DD65F3D-EB57-4AB3-BB33-81B42D460AC4"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:ion7500:-:*:*:*:*:*:*:*","matchCriteriaId":"9DC9074B-EA61-4D44-8A16-9E117138629A"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:ion7600:-:*:*:*:*:*:*:*","matchCriteriaId":"CFC7C001-9AB5-453F-BC3B-5544627B06CF"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:ion8650:-:*:*:*:*:*:*:*","matchCriteriaId":"1DA97CA0-DDE0-4418-9D72-7D463C003693"},{"vulnerable":true,"criteria":"cpe:2.3:h:schneider-electric:ion8800:-:*:*:*:*:*:*:*","matchCriteriaId":"B3449157-3715-4D89-A3BD-49EE47160B25"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2016","CveId":"5809","Ordinal":"1","Title":"CVE-2016-5809","CVE":"CVE-2016-5809","Year":"2016"},"notes":[{"CveYear":"2016","CveId":"5809","Ordinal":"1","NoteData":"An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.","Type":"Description","Title":"CVE-2016-5809"},{"CveYear":"2016","CveId":"5809","Ordinal":"2","NoteData":"2017-02-13","Type":"Other","Title":"Published"},{"CveYear":"2016","CveId":"5809","Ordinal":"3","NoteData":"2018-05-19","Type":"Other","Title":"Modified"}]}}}