{"api_version":"1","generated_at":"2026-07-24T17:28:56+00:00","cve":"CVE-2016-8358","urls":{"html":"https://cve.report/CVE-2016-8358","api":"https://cve.report/api/cve/CVE-2016-8358.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2016-8358","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2016-8358"},"summary":{"title":"CVE-2016-8358","description":"An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.","state":"PUBLISHED","assigner":"icscert","published_at":"2017-02-13 22:59:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-346","Smiths-Medical CADD-Solis Medication Safety Software MITM"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"8.5","severity":"HIGH","vector":"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"6","severity":"","vector":"AV:N/AC:M/Au:S/C:P/I:P/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:S/C:P/I:P/A:P","baseScore":6,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01","name":"https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Smiths-Medical CADD-Solis Medication Safety Software Vulnerabilities | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/94630","name":"http://www.securityfocus.com/bid/94630","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Smiths-Medical CADD-Solis Medication Safety Software Multiple Security Bypass Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2016-8358","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2016-8358","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Smiths-Medical CADD-Solis Medication Safety Software through 3.1","version":"affected Smiths-Medical CADD-Solis Medication Safety Software through 3.1","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2016","cve_id":"8358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"smiths-medical","cpe5":"cadd-solis_medication_safety_software","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"smiths-medical","cpe5":"cadd-solis_medication_safety_software","cpe6":"2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"smiths-medical","cpe5":"cadd-solis_medication_safety_software","cpe6":"3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"smiths-medical","cpe5":"cadd-solis_medication_safety_software","cpe6":"3.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T02:20:30.891Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01"},{"name":"94630","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/94630"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"Smiths-Medical CADD-Solis Medication Safety Software through 3.1","vendor":"n/a","versions":[{"status":"affected","version":"Smiths-Medical CADD-Solis Medication Safety Software through 3.1"}]}],"datePublic":"2017-02-13T00:00:00.000Z","descriptions":[{"lang":"en","value":"An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints."}],"problemTypes":[{"descriptions":[{"description":"Smiths-Medical CADD-Solis Medication Safety Software MITM","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-02-14T10:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01"},{"name":"94630","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/94630"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2016-8358","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Smiths-Medical CADD-Solis Medication Safety Software through 3.1","version":{"version_data":[{"version_value":"Smiths-Medical CADD-Solis Medication Safety Software through 3.1"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Smiths-Medical CADD-Solis Medication Safety Software MITM"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01"},{"name":"94630","refsource":"BID","url":"http://www.securityfocus.com/bid/94630"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2016-8358","datePublished":"2017-02-13T22:00:00.000Z","dateReserved":"2016-09-28T00:00:00.000Z","dateUpdated":"2024-08-06T02:20:30.891Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-02-13 22:59:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-346","Smiths-Medical CADD-Solis Medication Safety Software MITM"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:S/C:P/I:P/A:P","baseScore":6,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":6.8,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:1.0:*:*:*:*:*:*:*","matchCriteriaId":"AF207912-1122-4D34-A793-0FE76E158E0E"},{"vulnerable":true,"criteria":"cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:2.0:*:*:*:*:*:*:*","matchCriteriaId":"D8F550F1-8996-45F9-9676-5E1DBC0EA8EB"},{"vulnerable":true,"criteria":"cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:3.0:*:*:*:*:*:*:*","matchCriteriaId":"9FC5553F-6BF6-41CB-B70D-96BD73DFD232"},{"vulnerable":true,"criteria":"cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:3.1:*:*:*:*:*:*:*","matchCriteriaId":"7DF8B46B-7A15-4B90-927B-681B8C3B0411"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2016","CveId":"8358","Ordinal":"1","Title":"CVE-2016-8358","CVE":"CVE-2016-8358","Year":"2016"},"notes":[{"CveYear":"2016","CveId":"8358","Ordinal":"1","NoteData":"An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.","Type":"Description","Title":"CVE-2016-8358"},{"CveYear":"2016","CveId":"8358","Ordinal":"2","NoteData":"2017-02-13","Type":"Other","Title":"Published"},{"CveYear":"2016","CveId":"8358","Ordinal":"3","NoteData":"2017-02-14","Type":"Other","Title":"Modified"}]}}}