{"api_version":"1","generated_at":"2026-07-23T04:25:13+00:00","cve":"CVE-2016-8374","urls":{"html":"https://cve.report/CVE-2016-8374","api":"https://cve.report/api/cve/CVE-2016-8374.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2016-8374","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2016-8374"},"summary":{"title":"CVE-2016-8374","description":"An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.","state":"PUBLISHED","assigner":"icscert","published_at":"2017-02-13 21:59:01","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-400","Schneider Electric Magelis HMI Resource Consumption"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"7.8","severity":"","vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Schneider Electric Magelis HMI Resource Consumption Vulnerabilities (Update A) | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/94093","name":"http://www.securityfocus.com/bid/94093","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Schneider Electric Magelis HMI Multiple Denial of Service Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2016-8374","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2016-8374","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Schneider Electric Magelis HMI","version":"affected Schneider Electric Magelis HMI","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_gto_advanced_optimum_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_gto_advanced_optimum_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_gtu_universal_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_gtu_universal_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_sto5_small_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_sto5_small_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_stu_small_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_stu_small_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_xbt_gh_advanced_hand-held_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_xbt_gh_advanced_hand-held_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_xbt_gk_advanced_touchscreen_panel_with_keyboard","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_xbt_gk_advanced_touchscreen_panel_with_keyboard_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_xbt_gtw_advanced_open_touchscreen_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_xbt_gtw_advanced_open_touchscreen_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"magelis_xbt_gt_advanced_touchscreen_panel","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2016","cve_id":"8374","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"magelis_xbt_gt_advanced_touchscreen_panel_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2016-8374","qid":"590489","title":"Schneider Electric Magelis HMI Resource Consumption (Update B) Multiple Vulnerabilities (ICSA-16-308-02)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-06T02:20:30.941Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02"},{"name":"94093","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/94093"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"Schneider Electric Magelis HMI","vendor":"n/a","versions":[{"status":"affected","version":"Schneider Electric Magelis HMI"}]}],"datePublic":"2017-02-13T00:00:00.000Z","descriptions":[{"lang":"en","value":"An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION."}],"problemTypes":[{"descriptions":[{"description":"Schneider Electric Magelis HMI Resource Consumption","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-02-14T10:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02"},{"name":"94093","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/94093"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2016-8374","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric Magelis HMI","version":{"version_data":[{"version_value":"Schneider Electric Magelis HMI"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Schneider Electric Magelis HMI Resource Consumption"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02"},{"name":"94093","refsource":"BID","url":"http://www.securityfocus.com/bid/94093"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2016-8374","datePublished":"2017-02-13T21:00:00.000Z","dateReserved":"2016-09-28T00:00:00.000Z","dateUpdated":"2024-08-06T02:20:30.941Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-02-13 21:59:01","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-400","Schneider Electric Magelis HMI Resource Consumption"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_gtu_universal_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"67686731-11C6-4A70-86EA-C20D4A5E00C0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_gtu_universal_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"9338C7D9-7F38-4B34-BDB0-95563240A189"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_gto_advanced_optimum_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"453B800A-F3A0-4B22-961E-67F2EBAB292D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_gto_advanced_optimum_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"DDCA8937-DC4C-41C1-A1CC-BF4DA36C942D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_sto5_small_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"6E0BA1A0-E0B9-46A0-86C4-4C82A2EFCFC9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_sto5_small_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"C4FFCC32-67D5-4120-8BA8-C56C860CFEE4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_stu_small_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"2DF991F7-68D1-489A-BEDF-468F38E8B481"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_stu_small_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"88823BB1-E5A0-4835-943F-C13EEA51F77A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_xbt_gh_advanced_hand-held_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"50F7724E-7DBF-499B-BCD1-A02B86478555"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_xbt_gh_advanced_hand-held_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"126EDAD4-D08C-42B0-A621-596FCA27CF80"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_xbt_gk_advanced_touchscreen_panel_with_keyboard_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"7B73A3B3-686C-4F64-A398-C4E810A36FF7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_xbt_gk_advanced_touchscreen_panel_with_keyboard:-:*:*:*:*:*:*:*","matchCriteriaId":"6B98FB31-BF55-48EA-A284-627C431090CF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_xbt_gt_advanced_touchscreen_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"48F17071-598B-4361-8AA4-E60DC1CF02AA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_xbt_gt_advanced_touchscreen_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"92DF2AF4-045C-4E8E-AF10-A3BC0C824419"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:magelis_xbt_gtw_advanced_open_touchscreen_panel_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"229C5A41-9D33-4224-9AD8-E4C683DDD7FF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:magelis_xbt_gtw_advanced_open_touchscreen_panel:-:*:*:*:*:*:*:*","matchCriteriaId":"735F7A66-E882-431B-B8C9-046289A20DF0"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2016","CveId":"8374","Ordinal":"1","Title":"CVE-2016-8374","CVE":"CVE-2016-8374","Year":"2016"},"notes":[{"CveYear":"2016","CveId":"8374","Ordinal":"1","NoteData":"An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.","Type":"Description","Title":"CVE-2016-8374"},{"CveYear":"2016","CveId":"8374","Ordinal":"2","NoteData":"2017-02-13","Type":"Other","Title":"Published"},{"CveYear":"2016","CveId":"8374","Ordinal":"3","NoteData":"2017-02-14","Type":"Other","Title":"Modified"}]}}}