{"api_version":"1","generated_at":"2026-07-23T22:22:13+00:00","cve":"CVE-2017-12090","urls":{"html":"https://cve.report/CVE-2017-12090","api":"https://cve.report/api/cve/CVE-2017-12090.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-12090","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-12090"},"summary":{"title":"CVE-2017-12090","description":"An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a device power cycle resulting in downtime for the device. An attacker can send one packet to trigger this vulnerability.","state":"PUBLIC","assigner":"talos-cna@cisco.com","published_at":"2018-04-05 21:29:00","updated_at":"2022-04-19 19:15:00"},"problem_types":["CWE-400"],"metrics":[],"references":[{"url":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0442","name":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0442","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"TALOS-2017-0442 -  Cisco Talos","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-12090","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-12090","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"12090","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"micrologix_1400","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12090","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"micrologix_1400","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12090","vulnerable":"1","versionEndIncluding":"21.2","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"micrologix_1400_b_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"talos-cna@cisco.com","DATE_PUBLIC":"2018-03-28T00:00:00","ID":"CVE-2017-12090","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Allen Bradley","version":{"version_data":[{"version_value":"Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15"}]}}]},"vendor_name":"Talos"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a device power cycle resulting in downtime for the device. An attacker can send one packet to trigger this vulnerability."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"denial of service"}]}]},"references":{"reference_data":[{"name":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0442","refsource":"MISC","url":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0442"}]},"impact":{"cvss":{"baseScore":7.7,"baseSeverity":"High","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H","version":"3.0"}}},"nvd":{"publishedDate":"2018-04-05 21:29:00","lastModifiedDate":"2022-04-19 19:15:00","problem_types":["CWE-400"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE","baseScore":7.8},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:rockwellautomation:micrologix_1400_b_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"21.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"12090","Ordinal":"109237","Title":"CVE-2017-12090","CVE":"CVE-2017-12090","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"12090","Ordinal":"1","NoteData":"An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a device power cycle resulting in downtime for the device. An attacker can send one packet to trigger this vulnerability.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"12090","Ordinal":"2","NoteData":"2018-04-05","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"12090","Ordinal":"3","NoteData":"2018-04-05","Type":"Other","Title":"Modified"}]}}}