{"api_version":"1","generated_at":"2026-04-22T19:48:10+00:00","cve":"CVE-2017-12728","urls":{"html":"https://cve.report/CVE-2017-12728","api":"https://cve.report/api/cve/CVE-2017-12728.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-12728","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-12728"},"summary":{"title":"CVE-2017-12728","description":"An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2017-10-05 01:29:00","updated_at":"2020-08-19 19:11:00"},"problem_types":["CWE-269"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/100668","name":"100668","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"SpiderControl SCADA Web Server CVE-2017-12728 Local Code Execution Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"SpiderControl SCADA Web Server | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-12728","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-12728","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"12728","vulnerable":"1","versionEndIncluding":"2.02.0007","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"spidercontrol","cpe5":"scada_webserver","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-12728","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SpiderControl SCADA Web Server","version":{"version_data":[{"version_value":"SpiderControl SCADA Web Server"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-269"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"},{"name":"100668","refsource":"BID","url":"http://www.securityfocus.com/bid/100668"}]}},"nvd":{"publishedDate":"2017-10-05 01:29:00","lastModifiedDate":"2020-08-19 19:11:00","problem_types":["CWE-269"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:spidercontrol:scada_webserver:*:*:*:*:*:*:*:*","versionEndIncluding":"2.02.0007","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"12728","Ordinal":"109878","Title":"CVE-2017-12728","CVE":"CVE-2017-12728","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"12728","Ordinal":"1","NoteData":"An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"12728","Ordinal":"2","NoteData":"2017-10-04","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"12728","Ordinal":"3","NoteData":"2017-10-04","Type":"Other","Title":"Modified"}]}}}