{"api_version":"1","generated_at":"2026-04-23T06:18:08+00:00","cve":"CVE-2017-12732","urls":{"html":"https://cve.report/CVE-2017-12732","api":"https://cve.report/api/cve/CVE-2017-12732.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-12732","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-12732"},"summary":{"title":"CVE-2017-12732","description":"A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2017-10-05 21:29:00","updated_at":"2019-10-09 23:23:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/101174","name":"101174","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"GE CIMPLICITY CVE-2017-12732 Stack Based Buffer Overflow Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-278-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-278-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"GE CIMPLICITY (Update A) | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-12732","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-12732","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"12732","vulnerable":"1","versionEndIncluding":"9.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ge","cpe5":"intelligent_platforms_proficy_hmi/scada_cimplicity","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12732","vulnerable":"1","versionEndIncluding":"9.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ge","cpe5":"intelligent_platforms_proficy_hmi\\/scada_cimplicity","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-12732","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"GE CIMPLICITY","version":{"version_data":[{"version_value":"GE CIMPLICITY"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121"}]}]},"references":{"reference_data":[{"name":"101174","refsource":"BID","url":"http://www.securityfocus.com/bid/101174"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-278-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-278-01"}]}},"nvd":{"publishedDate":"2017-10-05 21:29:00","lastModifiedDate":"2019-10-09 23:23:00","problem_types":["CWE-119"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":6.8,"baseSeverity":"MEDIUM"},"exploitabilityScore":0.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:A/AC:M/Au:S/C:P/I:P/A:P","accessVector":"ADJACENT_NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.9},"severity":"MEDIUM","exploitabilityScore":4.4,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:*:*:*:*:*:*:*:*","versionEndIncluding":"9.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"12732","Ordinal":"109882","Title":"CVE-2017-12732","CVE":"CVE-2017-12732","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"12732","Ordinal":"1","NoteData":"A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"12732","Ordinal":"2","NoteData":"2017-10-05","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"12732","Ordinal":"3","NoteData":"2017-10-06","Type":"Other","Title":"Modified"}]}}}