{"api_version":"1","generated_at":"2026-07-23T10:06:05+00:00","cve":"CVE-2017-12738","urls":{"html":"https://cve.report/CVE-2017-12738","api":"https://cve.report/api/cve/CVE-2017-12738.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-12738","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-12738"},"summary":{"title":"CVE-2017-12738","description":"An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.","state":"PUBLISHED","assigner":"siemens","published_at":"2017-11-15 08:29:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-79","XSS"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"6.1","severity":"MEDIUM","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"4.3","severity":"","vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"}}],"references":[{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-164516.pdf","name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-164516.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Vendor Advisory"],"title":"Siemens","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"http://www.securityfocus.com/bid/101884","name":"http://www.securityfocus.com/bid/101884","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Multiple Siemens SICAM RTU Products Multiple Security Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-12738","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-12738","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00","version":"affected Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"12738","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sm-2556","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12738","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sm-2556_firmware","cpe6":"dnpi00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12738","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sm-2556_firmware","cpe6":"enos00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12738","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sm-2556_firmware","cpe6":"erac00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12738","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sm-2556_firmware","cpe6":"eta2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12738","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sm-2556_firmware","cpe6":"etls00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"12738","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sm-2556_firmware","cpe6":"modi00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2017","cve_id":"12738","cve":"CVE-2017-12738","epss":"0.002190000","percentile":"0.443930000","score_date":"2026-05-13","updated_at":"2026-05-14 00:03:18"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T18:43:56.530Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-164516.pdf"},{"name":"101884","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/101884"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00","vendor":"n/a","versions":[{"status":"affected","version":"Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00"}]}],"datePublic":"2017-11-15T00:00:00.000Z","descriptions":[{"lang":"en","value":"An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link."}],"problemTypes":[{"descriptions":[{"description":"XSS","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-11-21T10:57:01.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-164516.pdf"},{"name":"101884","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/101884"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2017-12738","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00","version":{"version_data":[{"version_value":"Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"XSS"}]}]},"references":{"reference_data":[{"name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-164516.pdf","refsource":"CONFIRM","url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-164516.pdf"},{"name":"101884","refsource":"BID","url":"http://www.securityfocus.com/bid/101884"}]}}}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2017-12738","datePublished":"2017-11-15T08:00:00.000Z","dateReserved":"2017-08-09T00:00:00.000Z","dateUpdated":"2024-08-05T18:43:56.530Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-11-15 08:29:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-79","XSS"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sm-2556_firmware:dnpi00:*:*:*:*:*:*:*","matchCriteriaId":"ED5101E6-6539-4764-AA69-04F231B579F3"},{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sm-2556_firmware:enos00:*:*:*:*:*:*:*","matchCriteriaId":"E03424AF-2BF9-4F1D-98A2-A98D9D413ACF"},{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sm-2556_firmware:erac00:*:*:*:*:*:*:*","matchCriteriaId":"407642BA-53E7-4D3E-8068-0817BB490953"},{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sm-2556_firmware:eta2:*:*:*:*:*:*:*","matchCriteriaId":"972FB974-D711-475F-88F1-5617929D7319"},{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sm-2556_firmware:etls00:*:*:*:*:*:*:*","matchCriteriaId":"80F5FF04-9652-464E-A7CB-490538BE26E2"},{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sm-2556_firmware:modi00:*:*:*:*:*:*:*","matchCriteriaId":"8B8337D2-8A9C-4554-8B2C-808F59D7F35B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sm-2556:-:*:*:*:*:*:*:*","matchCriteriaId":"1D7A2477-9462-47A8-A91F-8771F82B6615"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"12738","Ordinal":"1","Title":"CVE-2017-12738","CVE":"CVE-2017-12738","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"12738","Ordinal":"1","NoteData":"An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.","Type":"Description","Title":"CVE-2017-12738"},{"CveYear":"2017","CveId":"12738","Ordinal":"2","NoteData":"2017-11-15","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"12738","Ordinal":"3","NoteData":"2017-11-21","Type":"Other","Title":"Modified"}]}}}