{"api_version":"1","generated_at":"2026-07-23T10:01:58+00:00","cve":"CVE-2017-12785","urls":{"html":"https://cve.report/CVE-2017-12785","api":"https://cve.report/api/cve/CVE-2017-12785.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-12785","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-12785"},"summary":{"title":"CVE-2017-12785","description":"The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the \"show log cli\" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2017-08-22 17:29:00","updated_at":"2017-08-29 18:48:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"https://www.exploit-db.com/exploits/42518/","name":"42518","refsource":"EXPLOIT-DB","tags":["Third Party Advisory","VDB Entry"],"title":"NoviFlow NoviWare < NW400.2.6 - Multiple Vulnerabilities - Hardware dos Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-12785","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-12785","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"12785","vulnerable":"1","versionEndIncluding":"400.2.6","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"noviflow","cpe5":"noviware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2017-12785","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the \"show log cli\" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"42518","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/42518/"}]}},"nvd":{"publishedDate":"2017-08-22 17:29:00","lastModifiedDate":"2017-08-29 18:48:00","problem_types":["CWE-119"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":10},"severity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:noviflow:noviware:*:*:*:*:*:*:*:*","versionEndIncluding":"400.2.6","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"12785","Ordinal":"109935","Title":"CVE-2017-12785","CVE":"CVE-2017-12785","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"12785","Ordinal":"1","NoteData":"The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the \"show log cli\" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"12785","Ordinal":"2","NoteData":"2017-08-22","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"12785","Ordinal":"3","NoteData":"2017-08-22","Type":"Other","Title":"Modified"}]}}}