{"api_version":"1","generated_at":"2026-04-22T19:48:10+00:00","cve":"CVE-2017-13995","urls":{"html":"https://cve.report/CVE-2017-13995","api":"https://cve.report/api/cve/CVE-2017-13995.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-13995","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-13995"},"summary":{"title":"CVE-2017-13995","description":"An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2017-10-05 01:29:00","updated_at":"2019-10-09 23:23:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"iniNet Solutions GmbH SCADA Webserver | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/100951","name":"100951","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"IniNet Solutions SCADA Web Server CVE-2017-13995 Authentication Bypass Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-13995","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-13995","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"13995","vulnerable":"1","versionEndIncluding":"2.02.0000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"spidercontrol","cpe5":"ininet_webserver","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-13995","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"iniNet Solutions GmbH SCADA Webserver","version":{"version_data":[{"version_value":"iniNet Solutions GmbH SCADA Webserver"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-287"}]}]},"references":{"reference_data":[{"name":"100951","refsource":"BID","url":"http://www.securityfocus.com/bid/100951"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"}]}},"nvd":{"publishedDate":"2017-10-05 01:29:00","lastModifiedDate":"2019-10-09 23:23:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:spidercontrol:ininet_webserver:*:*:*:*:*:*:*:*","versionEndIncluding":"2.02.0000","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"13995","Ordinal":"111420","Title":"CVE-2017-13995","CVE":"CVE-2017-13995","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"13995","Ordinal":"1","NoteData":"An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"13995","Ordinal":"2","NoteData":"2017-10-04","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"13995","Ordinal":"3","NoteData":"2017-10-04","Type":"Other","Title":"Modified"}]}}}