{"api_version":"1","generated_at":"2026-07-17T17:03:02+00:00","cve":"CVE-2017-14020","urls":{"html":"https://cve.report/CVE-2017-14020","api":"https://cve.report/api/cve/CVE-2017-14020.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-14020","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-14020"},"summary":{"title":"CVE-2017-14020","description":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","state":"PUBLISHED","assigner":"icscert","published_at":"2017-11-13 20:29:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-427","CWE-427 UNCONTROLLED SEARCH PATH ELEMENT CWE-427"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"7.8","severity":"HIGH","vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"9.3","severity":"","vector":"AV:N/AC:M/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"http://www.securityfocus.com/bid/101780","name":"http://www.securityfocus.com/bid/101780","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Multiple AutomationDirect Products CVE-2017-1402 DLL Loading Local Code Execution Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Issue Tracking","Mitigation","Third Party Advisory","US Government Resource"],"title":"ICS-CERT Advisories | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-14020","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-14020","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"AutomationDirect","product":"CLICK Programming Software (Part Number C0-PGMSW)","version":"affected 2.10 and prior","platforms":[]},{"source":"CNA","vendor":"AutomationDirect","product":"C-More Programming Software (Part Number EA9-PGMSW)","version":"affected 6.30 and prior","platforms":[]},{"source":"CNA","vendor":"AutomationDirect","product":"C-More Micro (Part Number EA-PGMSW)","version":"affected 4.20.01.0 and prior","platforms":[]},{"source":"CNA","vendor":"AutomationDirect","product":"Do-more Designer Software (Part Number DM-PGMSW)","version":"affected 2.0.3 and prior","platforms":[]},{"source":"CNA","vendor":"AutomationDirect","product":"GS Drives Configuration Software (Part Number GSOFT)","version":"affected 4.0.6 and prior","platforms":[]},{"source":"CNA","vendor":"AutomationDirect","product":"SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT)","version":"affected 1.1.0.5 and prior","platforms":[]},{"source":"CNA","vendor":"AutomationDirect","product":"DirectSOFT Programming Software","version":"affected 6.1 and prior","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"14020","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"automationdirect","cpe5":"c-more_micro","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"1","versionEndIncluding":"4.20.01.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"automationdirect","cpe5":"c-more_micro_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"automationdirect","cpe5":"c-more_plc","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"1","versionEndIncluding":"6.30","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"automationdirect","cpe5":"c-more_plc_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"automationdirect","cpe5":"click_plc","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"1","versionEndIncluding":"2.10","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"automationdirect","cpe5":"click_plc_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"automationdirect","cpe5":"gs_drives","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"1","versionEndIncluding":"4.0.6","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"automationdirect","cpe5":"gs_drives_fimware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"automationdirect","cpe5":"sl-soft_solo_temperature_controller","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"14020","vulnerable":"1","versionEndIncluding":"1.1.0.5","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"automationdirect","cpe5":"sl-soft_solo_temperature_controller_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2017","cve_id":"14020","cve":"CVE-2017-14020","epss":"0.001270000","percentile":"0.316050000","score_date":"2026-05-13","updated_at":"2026-05-14 00:03:18"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T19:13:41.758Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"101780","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/101780"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"CLICK Programming Software (Part Number C0-PGMSW)","vendor":"AutomationDirect","versions":[{"status":"affected","version":"2.10 and prior"}]},{"product":"C-More Programming Software (Part Number EA9-PGMSW)","vendor":"AutomationDirect","versions":[{"status":"affected","version":"6.30 and prior"}]},{"product":"C-More Micro (Part Number EA-PGMSW)","vendor":"AutomationDirect","versions":[{"status":"affected","version":"4.20.01.0 and prior"}]},{"product":"Do-more Designer Software (Part Number DM-PGMSW)","vendor":"AutomationDirect","versions":[{"status":"affected","version":"2.0.3 and prior"}]},{"product":"GS Drives Configuration Software (Part Number GSOFT)","vendor":"AutomationDirect","versions":[{"status":"affected","version":"4.0.6 and prior"}]},{"product":"SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT)","vendor":"AutomationDirect","versions":[{"status":"affected","version":"1.1.0.5 and prior"}]},{"product":"DirectSOFT Programming Software","vendor":"AutomationDirect","versions":[{"status":"affected","version":"6.1 and prior"}]}],"datePublic":"2017-11-09T00:00:00.000Z","descriptions":[{"lang":"en","value":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-427","description":"UNCONTROLLED SEARCH PATH ELEMENT CWE-427","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2018-07-31T20:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"name":"101780","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/101780"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2017-11-09T00:00:00","ID":"CVE-2017-14020","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"CLICK Programming Software (Part Number C0-PGMSW)","version":{"version_data":[{"version_value":"2.10 and prior"}]}},{"product_name":"C-More Programming Software (Part Number EA9-PGMSW)","version":{"version_data":[{"version_value":"6.30 and prior"}]}},{"product_name":"C-More Micro (Part Number EA-PGMSW)","version":{"version_data":[{"version_value":"4.20.01.0 and prior"}]}},{"product_name":"Do-more Designer Software (Part Number DM-PGMSW)","version":{"version_data":[{"version_value":"2.0.3 and prior"}]}},{"product_name":"GS Drives Configuration Software (Part Number GSOFT)","version":{"version_data":[{"version_value":"4.0.6 and prior"}]}},{"product_name":"SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT)","version":{"version_data":[{"version_value":"1.1.0.5 and prior"}]}},{"product_name":"DirectSOFT Programming Software","version":{"version_data":[{"version_value":"6.1 and prior"}]}}]},"vendor_name":"AutomationDirect"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"UNCONTROLLED SEARCH PATH ELEMENT CWE-427"}]}]},"references":{"reference_data":[{"name":"101780","refsource":"BID","url":"http://www.securityfocus.com/bid/101780"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-01"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2017-14020","datePublished":"2017-11-13T20:00:00.000Z","dateReserved":"2017-08-30T00:00:00.000Z","dateUpdated":"2024-09-17T02:16:03.522Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-11-13 20:29:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-427","CWE-427 UNCONTROLLED SEARCH PATH ELEMENT CWE-427"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:automationdirect:click_plc_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.10","matchCriteriaId":"17150C6A-62A1-46BE-BBC2-4FDE9C2C7FE3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:automationdirect:click_plc:-:*:*:*:*:*:*:*","matchCriteriaId":"1C1B2940-104B-4ED2-B8DD-2B35A427A624"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:automationdirect:c-more_plc_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"6.30","matchCriteriaId":"AE0EACAD-45F4-41C6-A931-AB663F9B3820"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:automationdirect:c-more_plc:-:*:*:*:*:*:*:*","matchCriteriaId":"396C2928-5895-40CC-BCF2-3B8D607B34BA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:automationdirect:c-more_micro_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"4.20.01.0","matchCriteriaId":"AD7929CC-AE1E-461E-AD6D-EF3BD50E6AE5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:automationdirect:c-more_micro:-:*:*:*:*:*:*:*","matchCriteriaId":"DAE71D4F-EC67-4567-8BCB-653931016C99"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:automationdirect:gs_drives_fimware:*:*:*:*:*:*:*:*","versionEndIncluding":"4.0.6","matchCriteriaId":"A615B38E-7FA3-4DD6-8544-8002C13615C1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:automationdirect:gs_drives:-:*:*:*:*:*:*:*","matchCriteriaId":"CCEE1F6B-325F-414B-884D-8781D1F53B9C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:automationdirect:sl-soft_solo_temperature_controller_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.1.0.5","matchCriteriaId":"EC734917-5626-4917-B16E-737650077234"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:automationdirect:sl-soft_solo_temperature_controller:-:*:*:*:*:*:*:*","matchCriteriaId":"5D1849FB-D169-4610-A246-5DC6BC063234"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"14020","Ordinal":"1","Title":"CVE-2017-14020","CVE":"CVE-2017-14020","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"14020","Ordinal":"1","NoteData":"In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.","Type":"Description","Title":"CVE-2017-14020"},{"CveYear":"2017","CveId":"14020","Ordinal":"2","NoteData":"2017-11-13","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"14020","Ordinal":"3","NoteData":"2018-07-31","Type":"Other","Title":"Modified"}]}}}