{"api_version":"1","generated_at":"2026-07-23T20:30:07+00:00","cve":"CVE-2017-14616","urls":{"html":"https://cve.report/CVE-2017-14616","api":"https://cve.report/api/cve/CVE-2017-14616.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-14616","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-14616"},"summary":{"title":"CVE-2017-14616","description":"An FBX-5312 issue was discovered in WatchGuard Fireware before 12.0. If a login attempt is made in the XML-RPC interface with an XML message containing an empty member element, the wgagent crashes, logging out any user with a session opened in the UI. By continuously executing the failed login attempts, UI management of the device becomes impossible.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2017-09-20 20:29:00","updated_at":"2017-10-04 17:16:00"},"problem_types":["CWE-400"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/archive/1/540427","name":"http://www.securityfocus.com/archive/1/540427","refsource":"MISC","tags":["Third Party Advisory","VDB Entry"],"title":"SecurityFocus","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.sidertia.com/Home/Community/Blog/2017/09/18/Fixed-Fireware-XXE-DOS-and-stored-XSS-vulnerabilities-discovered-by-Sidertia","name":"https://www.sidertia.com/Home/Community/Blog/2017/09/18/Fixed-Fireware-XXE-DOS-and-stored-XSS-vulnerabilities-discovered-by-Sidertia","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"Página no encontrada | Sidertia Solutions","mime":"text/html","httpstatus":"404","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-14616","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-14616","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"14616","vulnerable":"1","versionEndIncluding":"11.12.4","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"watchguard","cpe5":"fireware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2017-14616","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An FBX-5312 issue was discovered in WatchGuard Fireware before 12.0. If a login attempt is made in the XML-RPC interface with an XML message containing an empty member element, the wgagent crashes, logging out any user with a session opened in the UI. By continuously executing the failed login attempts, UI management of the device becomes impossible."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.securityfocus.com/archive/1/540427","refsource":"MISC","url":"http://www.securityfocus.com/archive/1/540427"},{"name":"https://www.sidertia.com/Home/Community/Blog/2017/09/18/Fixed-Fireware-XXE-DOS-and-stored-XSS-vulnerabilities-discovered-by-Sidertia","refsource":"MISC","url":"https://www.sidertia.com/Home/Community/Blog/2017/09/18/Fixed-Fireware-XXE-DOS-and-stored-XSS-vulnerabilities-discovered-by-Sidertia"}]}},"nvd":{"publishedDate":"2017-09-20 20:29:00","lastModifiedDate":"2017-10-04 17:16:00","problem_types":["CWE-400"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE","baseScore":7.8},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:watchguard:fireware:*:*:*:*:*:*:*:*","versionEndIncluding":"11.12.4","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"14616","Ordinal":"112085","Title":"CVE-2017-14616","CVE":"CVE-2017-14616","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"14616","Ordinal":"1","NoteData":"An FBX-5312 issue was discovered in WatchGuard Fireware before 12.0. If a login attempt is made in the XML-RPC interface with an XML message containing an empty member element, the wgagent crashes, logging out any user with a session opened in the UI. By continuously executing the failed login attempts, UI management of the device becomes impossible.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"14616","Ordinal":"2","NoteData":"2017-09-20","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"14616","Ordinal":"3","NoteData":"2017-09-20","Type":"Other","Title":"Modified"}]}}}